background image

Paste Natural gas convertion label

9

Conversion Instructions

Installation should be done by a qualified service person.

Perform a Leak Check and Follow Up Lighting Instruction

10

VFK1702W-C-EF-NG Convsesion Label-F100

·

ATTENTION: This unit has been converted for use with Natural Gas.

Convert model# GBC1707WT-C, GBC1856W-C, GBC1768WC-C, GBC1870W-C.
Convert gas type: Natural Gas  
Manifold pressure: 7”
Input rate after conversion: 
GBC1707WT-C (30,000 BTU);
GBC1856W-C (48,000 BTU main  12,000 BTU side burner);
GBC1768WC-C (60,000 BTU main  12,000 BTU side burner); 
GBC1870W-C (40,000 BTU main  12,000 BTU main twin  12,000 BTU side burner).
This appliance was converted on _______(day-month-year) to Natural gas with Kit No. _______by __________________
(name and address of organization making this conversion), which accepts the responsibility that this conversion has been properly made.

·

ATTENTION: Ce barbecue a été modifié afin de pouvoir être utilisé avec du gaz naturel.

Convertissez le modèle # GBC1707WT-C, GBC1856W-C, GBC1768WC-C, GBC1870W-C.
Type de gaz de conversion: Gaz Naturel  
Pression du manifold: 7"
Taux d'entrée après conversion:
GBC1707WT-C (30 000 BTU);
GBC1856W-C (Brûleur principal de 48 000 BTU + brûleur latéral de 12 000 BTU);
GBC1768WC-C (Brûleur principal de 60,000 BTU + brûleur latéral de 12,000 BTU); 
GBC1870W-C (Brûleur principal de 40 000 BTU + double brûleur principal de 12 000 BTU + brûleur latéral de 12 000 BTU).
Cet appareil a été converti sur _____________ (jour-mois-année) au gaz naturel avec le kit no. _______by __________________ 
(nom et adresse de l'Organisation effectuant cette conversion), qui accepte la responsabilité que cette conversion a été faite correctement.

   

   

VFK1702W

-C-EF-N

G Convses

ion Lab

el-F100

·

ATTENTION:

 This unit

 has been 

convert

ed for use with Natura

l Gas.

Convert

 model

# GBC

1707W

T-C, GBC

1856W-C

, GBC1768WC-C

, GBC1870

W-C.

Convert

 gas type

: Natural

 Gas  

Manifold pres

sure: 7”

Input

 rate after

 convers

ion: 

GBC1707W

T-C (30,

000 BTU)

;

GBC1856

W-C (48,

000 BTU

 main burner

 + 12,000

 BTU side

 burner)

;

GBC1768WC-C

 (60,000

 BTU mai

n burner

 + 12,000

 BTU side

 burner)

GBC1870

W-C (40,

000 BTU

 main burner

 + 12,000

 BTU mai

n twin burner

 + 12,000

 BTU side

 burner)

.

This appl

iance was

 convert

ed on _______(

day-month-yea

r) to Natura

l gas wit

h Kit No

. _______by

 __________________

(name

 and address

 of orga

nization

 maki

ng this conversion)

, which

 accept

s the res

ponsibil

ity that this

 conversi

on has

 been

 properly

 made.

·

ATTEN

TION: Ce ba

rbecue 

a été 

modifié afi

n de pouvoi

r être 

utilisé avec 

du gaz na

turel.

Convert

issez le modèle # 

GBC1707WT-C,

 GBC1856W-C

, GBC1768WC-C

, GBC1870W-C.

Type d

e gaz de convers

ion: Gaz 

Naturel

  

Pression 

du mani

fold: 7"

Taux d'entrée 

après conversion:

GBC1707WT-C

 (30 000 

BTU);

GBC1856W-C

 (Brûleur pri

ncipal

 de 48 

000 BTU +

 brûleur l

atéral de 12 

000 BTU)

;

GBC1768WC-C

 (Brûleur pri

ncipal

 de 60,

000 BTU

 + brûleur l

atéral de 12,

000 BTU)

GBC1870W-C 

(Brûleur pri

ncipal

 de 40 

000 BTU +

 double 

brûleur pri

ncipal

 de 12 

000 BTU 

+ brûleur l

atéral de

 12 000 

BTU).

Cet appa

reil a été 

convert

i sur _____________ 

(jour-mois-a

nnée)

 au gaz 

naturel 

avec le kit

 no. ____

___by 

__________________ 

(nom et 

adresse 

de l'Organis

ation ef

fectuant 

cette conv

ersion),

 qui accept

e la res

ponsa

bilité que cette 

conversion a

 été faite 

correct

ement

.

   

   

WARNING: 

This conversion kit shall be installed

 

by a qualified service agency in accordance with the 
manufacturer’s instructions and all applicable codes 
and requirements of the Authority Having Jurisdiction. 
If the information in these instructions is not followed 
exactly, a fire, explosion or production of carbon 
monoxide may result causing property damage, 
personal injury or loss of life. The qualified service 
agency is responsible for the proper installation of this 
kit. The installation is not proper and complete until 
the operation of the converted appliance is checked as 
specified in the manufacturer’s instructions supplied 
with the kit.
Convet model# GBC1707WT-C, GBC1856W-C, 
GBC1768WC-C, GBC1870W-C.
Convet gas type: Natural Gas
Manifold pressure: 7”
Input rate after conversion: GBC1707WT-C (30,000 BTU 
main burner), GBC1856W-C (48,000 BTU main burner 
+ 12,000 BTU side burner), GBC1768WC-C (60,000 BTU 
main 12,000 BTU side burner), GBC1870W-C 
(40,000 BTU main 12,000 BTU main twin 
12,000 BTU side burner).

Perform a leak check:

1, Do NOT operate if gas leak is present. Gas leaks may cause a fire or explosion.
2, You must follow all leak-checking procedures before operating. To prevent fire or explosion hazard when testing for a leak:
a. Always perform leak test before lighting the grill and each time the natural gas line is connected.
b. No smoking. Do NOT use or permit sources of ignition in the area while conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated area.
d. Do NOT use matches, lighters or a flame to check for leaks.
e. Do NOT use grills until any and all leaks are corrected.
If you are unable to stop a leak, turn natural gas main valve to “OFF.” Disconnect natural gas line. Call a gas appliance serviceman.

Lighting Instruction:

 

W

CAUTION: Keep outdoor gas cooking appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

 

W

CAUTION: Do NOT obstruct the flow of combustion and ventilation air.

 

W

CAUTION: Check and clean burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire.

 

W

CAUTION: Attempting to light the burner with the lid closed may cause an explosion.

1.  Open lid. 
2.  Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the burner/venturi tube.  A clogged burner tube can lead to a fire.
3.  All control knobs must be in the “    OFF” position.

4.  LP:

 Connect LP gas tank per “Installing LP Gas Tank” section. / 

NG:

 Connect NG main line per “Installing Natural Gas Line” section.

5.  LP:

 Turn LP gas tank valve to “OPEN.” / 

NG:

 Turn natural gas main valve to “ON.”

6.  Push and turn any control knob to   (HIGH). The burner should light. If it does not, repeat up to three times.
7.  If ignition does not occur in 5 seconds, turn burner control knob “    OFF,” wait 5 minutes, and repeat lighting procedure.  
8.  If igniter does not light burner, use a lit match secured with the Lighting Rod (included with grill) to light burners. Access the burners through the cooking grid and heat plates. Position lit match 

near side of burner.

Important:

 Always use the Lighting Rod (included) when lighting burners with a match.

9.  After lighting, observe the burner flame. Make sure all burner ports are lit and flame height matches illustration in above model’s instruction manual .
Note: Each burner lights independently - repeat steps 5-9 for the other burners.

Содержание VFK1702W-C

Страница 1: ...twin burner 12 000 BTU side burner This appliance was converted on _______ day month year to Natural gas with Kit No _______by __________________ name and address of organization making this conversion which accepts the responsibility that this conversion has been properly made ATTENTION Ce barbecue a été modifié afin de pouvoir être utilisé avec du gaz naturel Convertissez le modèle GBC1707WT C G...

Страница 2: ... side of the cart assembly Your grill may differ from illustrations shown in these instructions Installation should be done by a qualified service person 1 Remove Warming Rack Cooking Grid Heat Plate 2 Remove All Main Burners and Igniter Wires 3 Remove Side Burner and Igniter Wire 4 A Disconnect LP gas tank per Disconnecting LP Gas Tank instructions in your grills owner s manual B Remove warming r...

Страница 3: ...ly needed if your grill has a side burner Remove LP Gas Regulator Hose Assembly and Attach Natural Gas Hose Assembly 7 To reassemble follow these instructions in reverse and reassemble all parts to your grill in order Note After the side burner assembled please ensure the distance between the igniter electrode and flame hole on side burner is 5 5 mm 3 5 mm ...

Страница 4: ...été faite correctement WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the Authority Having Jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or l...

Страница 5: ...pécifié dans les instructions du fabricant fournies avec le kit Convet modèle GBC1707WT C GBC1856W C GBC1768WC C GBC1870W C Type de gaz convet Gaz naturel Pression du manifold 7 Taux d entrée après conversion GBC1707WT C Brûleur principal de 30 000 BTU GBC1856W C Brûleur principal de 48 000 BTU brûleur latéral 12 000 BTU GBC1768WC C Brûleur principal de 60 000 BTU brûleur latéral 12 000 BTU GBC187...

Страница 6: ...fice du brûleur latéral 6 Retirer toutes les pièces des orifices des brûleur principaux 5 latéral Remarque Ceci est necessaire uniquement si votre barbecue possède un brûleur latéral Pour remettre les pièces en place suivez ces instructions en sens inverse et remontez toutes les pièces du barbecue dans l ordre Remarque après avoir assemblé le brûleur latéral assurez vous que la distance entre l él...

Страница 7: ...le sur les illustrations Cette installation devrait être effectuée par un technicien qualifié Retirer le brûleur latéral et le fil de l allumeur 4 Retirer toutes les brûleurs principaux et le fil de l allumeur 3 Retirer le Grille de réchauffage la grille de cuisson et la plaque chauffante 2 1 A Débrancher la bouteille de propane en suivant les instructions du paragraphe Débrancher la bouteille de ...

Страница 8: ...l Gas Manifold pressure 7 Input rate after conversion GBC1707WT C 30 000 BTU GBC1856W C 48 000 BTU main burner 12 000 BTU side burner GBC1768WC C 60 000 BTU main burner 12 000 BTU side burner GBC1870W C 40 000 BTU main burner 12 000 BTU main twin burner 12 000 BTU side burner This appliance was converted on _______ day month year to Natural gas with Kit No _______by __________________ name and add...

Отзывы: