background image

Natural Gas Conversion Kit

This Natural Gas Conversion Kit can be used ONLY with 

the following approved grills:

Installation should be 

done by a qualified service 

person.

Use only RevoAce Inc. limited 
factory-authorized parts. The 
use of any part that is not 
factory-authorized can be 
dangerous and will void your 
warranty.

Tools Required for Conversion (Included)

Wrench 

1 pc

Manufactured in China for: RevoAce Inc. Limited

Hong Kong, China • 1.800.694.0013

VFK1702W-C-EF-OM-F102

Parts List 

1

Natural Gas Hose

B0507-B01

2

Quick Connect Couple

B0507-B02

3

3/8 in. Brass Adapter

B0507-B03

4

Natural Gas Label

B0507-B04

Expanded View

VFK1702W-C-EF-NG Convsesion Label-F100

·

ATTENTION: This unit has been converted for use with Natural Gas.

Convert model# GBC1707WT-C, GBC1856W-C, GBC1768WC-C, GBC1870W-C.
Convert gas type: Natural Gas  
Manifold pressure: 7”
Input rate after conversion: 
GBC1707WT-C (30,000 BTU);
GBC1856W-C (48,000 BTU main  12,000 BTU side burner);
GBC1768WC-C (60,000 BTU main  12,000 BTU side burner); 
GBC1870W-C (40,000 BTU main  12,000 BTU main twin  12,000 BTU side burner).
This appliance was converted on _______(day-month-year) to Natural gas with Kit No. _______by __________________
(name and address of organization making this conversion), which accepts the responsibility that this conversion has been properly made.

·

ATTENTION: Ce barbecue a été modifié afin de pouvoir être utilisé avec du gaz naturel.

Convertissez le modèle # GBC1707WT-C, GBC1856W-C, GBC1768WC-C, GBC1870W-C.
Type de gaz de conversion: Gaz Naturel  
Pression du manifold: 7"
Taux d'entrée après conversion:
GBC1707WT-C (30 000 BTU);
GBC1856W-C (Brûleur principal de 48 000 BTU + brûleur latéral de 12 000 BTU);
GBC1768WC-C (Brûleur principal de 60,000 BTU + brûleur latéral de 12,000 BTU); 
GBC1870W-C (Brûleur principal de 40 000 BTU + double brûleur principal de 12 000 BTU + brûleur latéral de 12 000 BTU).
Cet appareil a été converti sur _____________ (jour-mois-année) au gaz naturel avec le kit no. _______by __________________ 
(nom et adresse de l'Organisation effectuant cette conversion), qui accepte la responsabilité que cette conversion a été faite correctement.

1

2

3

4

OWNER’S MANUAL

Model Number VFK1702W-C

Tools Required for Conversion (Not Included)

#2 Phillips Head Screwdriver 

1 pc

M22 Wrench 

1 pc

®

®

®

GBC1707WT-C

GBC1856W-C

GBC1768WC-C

GBC1870W-C

®

Содержание VFK1702W-C

Страница 1: ...twin burner 12 000 BTU side burner This appliance was converted on _______ day month year to Natural gas with Kit No _______by __________________ name and address of organization making this conversion which accepts the responsibility that this conversion has been properly made ATTENTION Ce barbecue a été modifié afin de pouvoir être utilisé avec du gaz naturel Convertissez le modèle GBC1707WT C G...

Страница 2: ... side of the cart assembly Your grill may differ from illustrations shown in these instructions Installation should be done by a qualified service person 1 Remove Warming Rack Cooking Grid Heat Plate 2 Remove All Main Burners and Igniter Wires 3 Remove Side Burner and Igniter Wire 4 A Disconnect LP gas tank per Disconnecting LP Gas Tank instructions in your grills owner s manual B Remove warming r...

Страница 3: ...ly needed if your grill has a side burner Remove LP Gas Regulator Hose Assembly and Attach Natural Gas Hose Assembly 7 To reassemble follow these instructions in reverse and reassemble all parts to your grill in order Note After the side burner assembled please ensure the distance between the igniter electrode and flame hole on side burner is 5 5 mm 3 5 mm ...

Страница 4: ...été faite correctement WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the Authority Having Jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or l...

Страница 5: ...pécifié dans les instructions du fabricant fournies avec le kit Convet modèle GBC1707WT C GBC1856W C GBC1768WC C GBC1870W C Type de gaz convet Gaz naturel Pression du manifold 7 Taux d entrée après conversion GBC1707WT C Brûleur principal de 30 000 BTU GBC1856W C Brûleur principal de 48 000 BTU brûleur latéral 12 000 BTU GBC1768WC C Brûleur principal de 60 000 BTU brûleur latéral 12 000 BTU GBC187...

Страница 6: ...fice du brûleur latéral 6 Retirer toutes les pièces des orifices des brûleur principaux 5 latéral Remarque Ceci est necessaire uniquement si votre barbecue possède un brûleur latéral Pour remettre les pièces en place suivez ces instructions en sens inverse et remontez toutes les pièces du barbecue dans l ordre Remarque après avoir assemblé le brûleur latéral assurez vous que la distance entre l él...

Страница 7: ...le sur les illustrations Cette installation devrait être effectuée par un technicien qualifié Retirer le brûleur latéral et le fil de l allumeur 4 Retirer toutes les brûleurs principaux et le fil de l allumeur 3 Retirer le Grille de réchauffage la grille de cuisson et la plaque chauffante 2 1 A Débrancher la bouteille de propane en suivant les instructions du paragraphe Débrancher la bouteille de ...

Страница 8: ...l Gas Manifold pressure 7 Input rate after conversion GBC1707WT C 30 000 BTU GBC1856W C 48 000 BTU main burner 12 000 BTU side burner GBC1768WC C 60 000 BTU main burner 12 000 BTU side burner GBC1870W C 40 000 BTU main burner 12 000 BTU main twin burner 12 000 BTU side burner This appliance was converted on _______ day month year to Natural gas with Kit No _______by __________________ name and add...