11
9. Restore your gas supply and check ALL of the connections for leaks using a solution of
soapy water. If a leak is discovered and any bubbles are seen, close the main gas valve and
re-tighten
ALL the connections. NEVER USE A FLAME TO CHECK FOR GAS LEAKS!
Step5
10. Stick the conversion label on the rating plate as shown in Figure 10.
Metal Rating Plate
1.
2.
3.
4.
5.
6.
7.
Figure 1
7
Conversion Label
MAINTENANCE
The flames should look like those in Figure 11. To clean
the burner,
use a soft brush after the burner has cooled
completely. Never use a vacuum cleaner on the burner.
It is recommended to store the fire pit indoors during
winter if it will be subjected to freezing temperatures. The
LP cylinder must be disconnected and removed from the
appliance before the appliance can be stored indoors.
Figure 11
Serial
Number
_________________
Model
Number: WT17IL
CAUTION:
The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of
Minimum clearance from combustible constructions: Sides: 24 in.609 mm. Top 72 in. 1828 mm.
FOR OUTDOOR USE ONLY.
If stored indoors, detach and leave cylinder outdoors.
This appliance has been converted to use Natural Gas. Input 30,000 Btu/hr.
Max Gas Supply Pressure 7 inch w.c. (1.74 kPa) Min. Gas Supply Pressure 5 inch w.c. (1.24 kPa)
Figure 10