4.1 Battery Installation

The Pur•Chek™ has, as an option, an internal rechargeable battery.  If your Pur•Chek™ is equipped with the 
optional rechargeable battery, you must fi rst install and charge the battery prior to use.  NOTE:  The Pur•Chek™ 
can be operated with or without the battery using the supplied AC adapter.  Refer to Section 2.2 for instructions.

To install the optional battery, remove the battery cover from the back of the unit by unscrewing the two Phillips 
head screws as shown below.

OR OPENED CONTAINERS OF GASOLINE.

at least 18 inches above to floor.

Use this equipment in locations with mechanical ventilation that
provides at leat four air changes per hour or locate the equipment

D

A

TE

 C

ODE

:

WARNING-TO REDUCE THE RISK OF FIRE:

DO NOT USE THIS EQUIPMENT IN THE VICINITY OF SPILLED

LISTED         6P03

Design Pressure:  300 psig

Refrigerant Type: R-12, R-134a

R

Miscellaneous Refrigerant Equipment
12 VDC, 1A; Design Pressure: 300 psig

Battery Cover Screws

Inside the Pur•Chek™ battery compartment, locate the male plug on the left side.  Slide the nylon strap around 
the battery.  Insert the battery module into the compartment aligning the female connector of the battery module 
with the male plug in the battery compartment.  Replace the cover and snug the screws.

NOTE:

 Charge the battery for a minimum of 4 hours with the supplied charger prior to fi rst use.

To remove the battery, simply tug gently on the nylon strap, being sure to pull straight up, until the battery is 
dislodged.   The battery may be charged either inside of the unit or independent of the unit.

Содержание PUR-CHEK

Страница 1: ...Product Leadership Training Service Reliability Instruction 2100 9000 Operation and Maintenance Rev 0 June 2010...

Страница 2: ...LIEU OF I ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND II ANY OBLI GATION LIABILITY...

Страница 3: ...r 5 3 4 Control Panel 6 3 5 Back Panel Connections 6 3 6 Hard Shell Storage Carrying Case 7 4 Operation 8 4 1 Battery Installation 8 4 2 Turning On the Unit 9 4 3 Calibration 9 4 4 Viewing the Test Re...

Страница 4: ...Pur Chek Instruction 2100 9000 ii...

Страница 5: ...or adhered to could result in minor or moderate injury IMPORTANT The use of the word IMPORTANT in this manual calls attention to a procedure practice condition or the like which if not correctly perf...

Страница 6: ...or will not emit heavy loads of oil or liquid NEVER admit any sample into the instrument at pressures in excess of 500 psig 1 3 Features and Capabilities The Pur Chek HVAC Advanced Refrigerant Identif...

Страница 7: ...levels of purity based on their recovery or use standards Sample gas is admitted into the instrument through the supplied sample hose and presented to the sensing device The instrument provides the u...

Страница 8: ...unit The chart shown is for generic reference only Displays R410A Not suitable for R404A or R507A as they are presented as R134A Blend data shown below is for reference only at 70 F and should be veri...

Страница 9: ...e will handle all of the refrigerant transfer and will provide containment up to 300psig The outer tube will provide protection of the inner tube from abrasion nicking cutting etc The hose is provided...

Страница 10: ...e soft key label at the bottom of the graphic display Red and Green LED s at the top of the Control Panel are used for visual status indications Green LED Power On Off Soft Keys Red LED 3 5 Back Panel...

Страница 11: ...ll Storage Carrying Case The hard shell storage carrying case is custom fit to the Pur Chek It provides rugged protection for the instrument as well as convenient storage for all components The enclos...

Страница 12: ...nges per hour or locate the equipment DATE CODE WARNING TO REDUCE THE RISK OF FIRE DO NOT USE THIS EQUIPMENT IN THE VICINITY OF SPILLED LISTED 6P03 Design Pressure 300 psig Refrigerant Type R 12 R 134...

Страница 13: ...internal pump This fresh air purges any excess refrigerant from the unit and ensures accurate test results Calibration requires that the hose be disconnected from the refrigerant cylinder or air condi...

Страница 14: ...concentration is greater than 90 NON represents non condensable elements such as air or another dilut ing gas 4 5 Blend Refrigerants The Pur Chek includes the Blend Chek feature for determining the pr...

Страница 15: ...Additional printouts may be made following the same procedure To exit the test press the EXIT button Figures 14 15 16 show sample printouts for various test results Bacharach Inc Refrigerant Identifi...

Страница 16: ...he help screen Figure 17 TO SET THE ELEVATION PRESS ELEV BUNNON TO SET THE LCD CONTRAST PRESS CONT Figure 19 Figure 20 ELEV CONT DONE SET FEED DONE FEET METERS 400 122 5 2 Setting the LCD Contrast The...

Страница 17: ...the new filter into the retaining clip Inspect the sample hoses for signs of oil entrapment Replacement of the sample filter usually requires cleaning or replacement of the sample hoses 5 4 Cleaning t...

Страница 18: ...on the top of the printer press the STOP button Press the TEST button to print a test message and verify that the paper is installed properly Slide the paper through the slot in the printer door and c...

Страница 19: ...re Rechargeable Battery 2100 9000 Instruction Manual 7 Service Centers Service and replacement parts can be found by contacting any of the following Bacharach Service Centers United States Bacharach I...

Страница 20: ...Pur Chek Instruction 2100 9000 16 NOTES...

Страница 21: ...Pur Chek Instruction 2100 9000 17 NOTES...

Страница 22: ...ers 621 Hunt Valley Circle New Kensington PA 15068 PH 724 334 5000 Toll Free 800 736 4666 Fax 724 334 5001 Website www mybacharach com Email help mybacharach com Printed in USA Registered Trademark of...

Отзывы: