General Cautions 

 

ALWAYS

  wear  eye  and  skin  protection  when  working  with  refrigerants.  

Escaping  refrigerant  vapors  will  present  a  freezing  danger.  Do  NOT  direct 
refrigerant  escaping  from  the  sample  hose  toward  exposed  skin  or  toward 
the face. 

 

ALWAYS 

turn the compressor or automobile engine 

OFF

 before connecting 

the instrument to an air conditioning system. 

 
 

ALWAYS

  inspect  the sample  hose  before  each  use.    Replace  the  hose  if  it  appears 

cracked, frayed, obstructed or fouled with oil. 

 

DO NOT

 direct refrigerant vapors venting from hoses towards the skin. 

 

 

DO NOT

 disassemble the instrument.  There are no serviceable components 

internal to the instrument and disassembly will void the warranty. 

 

ALWAYS 

place the analyzer on a flat and sturdy surface. 

  To  reduce  the  risk  of  electrical  shock,  do  NOT  disassemble  the  instrument; 

do not use the instrument in wet or damp areas. 

  Some  systems  may  contain  hydrocarbons  or  flammable  refrigerants.    This 

analyzer  is  designed  with  sealed  heat  sources  and  without  sparking 
components.  Ensure  adequate  ventilation  and  always  take  proper 
precautions when working with refrigerants. 

 

DO NOT

 breathe refrigerant and lubricant vapor or mist. Exposure may irritate eyes, 

nose, and throat. Use recycling equipment certified to meet the requirements of SAE 
J2788, J2843, J3030 or J2851 to remove refrigerant from the A/C system. If accidental 
system  discharge  occurs,  immediately  ventilate  the  work  area.  There  must  be 
adequate ventilation in the vehicle servicing area. 

 

 

DO  NOT

  utilize  any  hose(s)  other  than  those  supplied  with  the  instrument.  

The use of other hose types will introduce errors into the refrigerant analysis 
and instrument calibration. 

 

ALWAYS

  verify  that  the  refrigerant,  tested  from  the  Low  Side,  does  not 

contain or will not emit heavy loads of oil or liquid. 

 

 

NEVER

 admit any sample into the instrument at pressures in excess of 

500 

psig

.  

 

NEVER

  obstruct  the  air  intake,  sample  exhaust  or  case  vent  ports  of  the 

instrument during use. 

 

DO NOT

 utilize the coupler supplied on the service end of the R-134a or R-

1234yf Sample Hoses for any application other than with the instrument.  The 
coupler  supplied  is  a  modified  version  that  does  not  contain  a  check  valve 
and is not suitable for any other refrigerant application. 

Содержание Neutronics LEGEND ID RI-2018 Series

Страница 1: ...56 Creamery Way Exton PA 19341 USA Phone 1 610 524 8800 Fax 1 610 524 8807 Email info refrigerantid com www refrigerantid com ACTIVATE SOFTWARE UPDATES BEFORE FIRST TEST www refrigerantid com activate...

Страница 2: ...Manual Part Number 5 06 7000 80 0 Manual File 012476 Rev A Page II...

Страница 3: ...Manual Part Number 5 06 7000 80 0 Manual File 012476 Rev A Page III LEGEND ID Model RI 2018 Series AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL...

Страница 4: ...USB Cord 1 12 R 1234yf and R 134a Tank Adapter Fittings 1 12 AC Power Adapter 1 13 Control Panel 1 13 Back Panel Connections 1 14 Hard Shell Storage Carrying Case 1 14 2 LEGEND IDTM OPERATION 2 15 2...

Страница 5: ...llow the manual can result in serious injury or death Less than 2 grams of refrigerant are vented with each sample This analyzer is designed with sealed heat sources and without sparking components o...

Страница 6: ...hout sparking components Ensure adequate ventilation and always take proper precautions when working with refrigerants DO NOT breathe refrigerant and lubricant vapor or mist Exposure may irritate eyes...

Страница 7: ...ion regarding the application operation or spare parts please contact the Neutronics Inc Customer Service Department If you have questions or comments we would like to hear from you Neutronics Inc 456...

Страница 8: ...by the SAE as a refrigerant mixture that contains 98 0 or greater of R 1234yf or R 134a by weight The instrument is supplied complete with an R 1234yf sample hose an R 134a sample hose R 12 coupler so...

Страница 9: ...ant sampled Capable of analyzing R 12 1 4 Flare coupler sold separately Multiple Languages o English German Spanish French Italian Portuguese Chinese Japanese Korean and Russian Easily prints test res...

Страница 10: ...therefore there are no serviceable components internal to the instrument and disassembly will void the warranty Legend R 1234yf Sample Hose The 6 5 foot 2 meter R 1234yf Sample Hose is constructed of...

Страница 11: ...le hose extensions allow the user to easily connect and disconnect the hose assembly to the analyzer The extension is connected directly to the analyzer and the sample hose connects to the male feral...

Страница 12: ...zer R 1234yf Tank Adapter Fitting The R 1234yf Tank Adapter Fitting will provide the user with an adapter to allow connection of the R 1234yf Sample Hose to the LH Acme threads on the R 1234yf cylinde...

Страница 13: ...harge the battery when connected to the analyzer NOTE Use of any other power source may cause damage to the unit and void the warranty Control Panel The Control Panel serves as the main user interface...

Страница 14: ...structed Keep the sample outlet port free and clear at all times Do not operate near open flame Hard Shell Storage Carrying Case The hard shell storage carrying case is custom fit to the Legend ID It...

Страница 15: ...2 2 Power On the Analyzer For use with an SAE J2843 or J3030 certified AC Service Machine connect one end of the provided USB cable to the USB port on the back of the analyzer and connect the other en...

Страница 16: ...or cylinder you must select R 134a mode 2 3 Calibration Each time the Legend ID begins a new test cycle it must complete an air calibration The calibration takes 30 seconds and pulls fresh air into t...

Страница 17: ...r a few seconds and then press the Test button to begin the test The Testing screen shown in Figure 8 will display 2 5 Viewing the Test Results Upon completion of testing the Legend ID will display Fi...

Страница 18: ...rigerant source and press Exit to return to the main screen Figure 11 NOTE In R 134a mode R 12 and R 1234yf are combined into one reading referred to as R 12 R 1234yf 2 6 Understanding Test Results Th...

Страница 19: ...the sampled refrigerant is found to be less than 95 presents hydrocarbons or a has large contamination the screen will illuminate Red and CAUTION SHOULD BE TAKEN WHEN HANDLING THIS VEHICLE OR CYLINDE...

Страница 20: ...lyzer 2 Remove the brass restrictor end with hose attached from the coupler and discard Be sure to use a backing wrench as not to damage the coupler 3 Check for signs of oil and debris in the coupler...

Страница 21: ...ER THE ANALYZER WE WILL NOT BE ABLE TO INFORM YOU OF ANY SOFTWARE UPDATES 3 4 Settings Pressing the Settings button as shown in Figure 18 will provide access to various device settings as shown in Fig...

Страница 22: ...hat the white filter is correctly plugged into the rubber grommets Error 4 The unit is beyond the operating temperature range Solution Move the unit to an area where the ambient temperature is within...

Страница 23: ...0 Legend R 1234yf Replacement Hose 6 02 6001 56 0 Legend R 134a Hose Kit 6 02 6001 57 0 Legend R 1234yf Hose Kit 4 2 Specifications SAMPLE PARAMETERS Vapor only oil free 500 psig 2 MPa Maximum DETECTE...

Страница 24: ...oceedings or other expenses Any description of the goods contained in any documents to which these warranty provisions relate including any quotations or purchase orders relating to the goods being de...

Отзывы: