4 - 33
In
spection and
Adjustment
Adjustment
Movable knife origin adjustment
1. Enter the test mode, and press [MAIN BOARD TEST MODE] and then [TRIM MOTOR TEST].
2. Press [MOVE ORIGIN POSITION] to move the needle plate base assembly's movable knife to its origin.
3. Loosen the 2 screws
1
.
4. Adjust the position the movable knife stops.
5. Tighten the 2 screws
1
.
Distance between edges of movable knife and
fixed knife
1 mm
1
Torque
0.78 - 1.18 N-m
Screw, Bind
M
3X4
1
1 mm