(24) Anchor bolts of cylinder brackets
4.5.17
Power pack is to be placed at exact posi�on in accordance with project layout, and connected with switching
cabinet.
4.5.18
Fill the power pack with sufficient hydraulic oil of quan�ty according to specific order.
Note:
In normal temperature, hydraulic oil L-HV 46# is recommend, and 32# for low temperature. Viscosity of
hydraulic oil should be 15 – 46 cst, and cleanness be NAS9 to NAS10. Hydraulic oil AFT Dexron III is acceptable as
well. Biodegradable hydraulic oil can be used as long as it’s abrasion-resistant and compa�ble with NBR O ring.
Automo�ve engine oil is not acceptable.
4.5.19
Switching cabinet is to be placed at exact posi�on in accordance with project layout, and connected with
opera�on panel.
4.5.20
Opera�on panel is to be fixed onto wall at exact posi�on in accordance with project layout.
4.5.21
Connect the main power supply to hydraulic power pack.
Note:
(1)
Protect power pack from hi�ng or damage during transporta�on, installa�on and storage to avoid any
product failure.
(2)
Power pack should be earthing properly according to local regula�on.
(3)
Make sure main power supply is turned off during wiring.
(4)
10% of rated voltage is acceptable maximum voltage loss.
(5)
Wires with larger wire diameter and as short as possible length
are
good for lowering voltage loss.
(6)
Star�ng with
a
voltage shortage will lead to abnormal opera�on or motor failure.
(7)
For 3 phase power supply, check whether
the
motor is rota�ng in
the
correct direc�on first once
connec�ng power
pack with main power supply.
(8)
Every O rings of all seals are to be lubricated by hydraulic oil and all seals are to be installed before fixing
power pack.
(9)
Do not bend oil hoses and wires too much. (the bending radius should be more than 9 �mes as outer
diameter of oil hose or wires)
(10)
Keep oil hoses and wires away from sharp items.
4.5.22
Loosen anchor bolts of both cylinder brackets.
Make
the
pla�orm move up and down several �mes by opera�on panel a�er turn
ing
on main switch and
switching cabinet. Chains will be self-adjusted to
the
proper posi�on during movement.
Then anchor bolts of both cylinder brackets are to be fixed again.