4.3 Fail Safe Selection 

 

      The failsafe feature provides a “false alarm” in case of power outage or major component failures. When

 

                    properly selected, the failsafe feature can protect equipment or alert you of a unit failure.  
 
 

       Fail Safe High (FSH) means that the relay is energized when NO PRODUCT is touching the sensing         

 

       element. The green led indicates relay status and is on when the relay is energized. When product comes 

 

       into contact with the probe, the relay is de-energized.  

 
 

       Fail Safe Low (FSL) means that the relay is energized when PRODUCT IS touching the probe. 

 
 
 
     

 

                       

 

4.4 Sensitivity Calibration 

 

 

       

The LS7000 should be calibrated when no material is touching the probe, when the unit is installed where 

 

       it will be used. 

 

 

1. Observe the Red LED. If it is on, go to Step 3 

 

 

2. If the Red LED is off, turn the sensitivity adjustment potentiometer clockwise (CW) until it comes 

 

 

     on. 

 

 

3. Turn the sensitivity adjustment pot counter-clockwise (CCW) until the Red LED just goes out. This 

 

 

     sets the unit to its maximum sensitivity. If in your application this is too sensitive, you can turn the 

 

 

     sensitivity adjustment pot further CCW; usually ¼ to ½ turn is sufficient to reduce the units                 

 

 

     sensitivity. Always bring the product into contact with the probe after calibration to assure proper 

 

 

     performance.  

 

 

 

  

 

     

NOTE:

 The green LED indicates relay status. The relay is energized when the green LED is on.

 

 

 

 

     

SPECIAL CALIBRATION NOTES: 

 

 

     For some products, the LS7000 can be calibrated with product touching the probe. To do this, turn 

 

 

     the sensitivity adjustment pot CW until the Red LED just comes on and continue CW for 1/8 to ¼ 

 

 

     of a turn. Always check to see if unit resets in the absence of product. 

NOTE:

 Due to the wide variety of applications and possible control or alarm functions, the proper fail   

 

safe selection will depend on your circumstances. Please call your distributor or the factory if 

 

you need assistance. 

 

Содержание LS7000

Страница 1: ...LS7000 LEVEL SWITCH OWNERS MANUAL INSTALLATION CALIBRATION TROUBLESHOOTING WARRANTY P O Box 70094 Houston TX 77270 713 467 4438...

Страница 2: ...r problems arise during installation please contact Customer Service 1 800 835 8012 or 713 467 4438 8 00 a m to 5 00 p m CST US Failure to follow safe installation and servicing guidelines could resul...

Страница 3: ...tion 5 1 4 GA Drawing 5 3 INSTALLATION 6 3 1 Inspection 6 3 2 Bench Test 6 3 3 Physical Installation 6 3 4 Removing the Electronics 7 3 5 Typical Applications and Wiring Diagrams 8 4 CALIBRATION 14 4...

Страница 4: ...rical Power 115 VAC 15 50 60 Hz 2 watts standard 12 VDC 24 VDC or 230 VAC optional Output 2 Form C contacts DPDT relay 5 amp resistive At 125 250 VAC 30 VDC Fuse On board 250 mA 125 volts Fail Safe Se...

Страница 5: ...www babbittinternational com Reference Manual 2021 5 1 3 Ordering Information 1 4 GA Drawing...

Страница 6: ...2 On the bench hook up the appropriate power to L1 and L2 The operating voltage of the LS7000 is marked on the power supply board Hold the unit so that nothing is touching any surface and press the t...

Страница 7: ...dry materials mount the LS7000 in the top of the vessel whenever possible This allows you to lengthen the probe if necessary b Avoid mounting the LS7000 near the product inlet vent return lines dust c...

Страница 8: ...ONTACTS SUPPLY VOLTAGE NOTE EACH LS7000 POWER SUPPLY IS INTENDED FOR ONLY ONE SUPPLY VOLTAGE THIS VOLTAGE IS PRINTED ON THE POWER SUPPLY BOARD FOR 115 VAC OR 230 VAC UNITS HOOK UP THE HOT LEAD TO L1 A...

Страница 9: ...www babbittinternational com Reference Manual 2021 9...

Страница 10: ...www babbittinternational com Reference Manual 2021 10...

Страница 11: ...www babbittinternational com Reference Manual 2021 11...

Страница 12: ...www babbittinternational com Reference Manual 2021 12...

Страница 13: ...www babbittinternational com Reference Manual 2021 13...

Страница 14: ...E S3 and S4 also select fail safe high level FSH or fail safe low level FSL 2 Select the timing range using S1 and S2 as shown on the chart below next page 3 Adjust the time adjustment potentiometer c...

Страница 15: ...djustment potentiometer clockwise CW until it comes on 3 Turn the sensitivity adjustment pot counter clockwise CCW until the Red LED just goes out This sets the unit to its maximum sensitivity If in y...

Страница 16: ...go out If it does repair replace or clean antenna probe If LED does not go out replace electronics Bad sensing card Repair or replace card Unit triggers when material Improper mount of probe Contact...

Страница 17: ...applied to any components which have been damaged by improper installation use exposure to unusual atmospheric conditions or components which have been misused abused damaged by neglect or accident Th...

Отзывы: