Configuration examples
Documentation
INTERCOMMODULE
36 BAB TECHNOLOGIE GmbH
INTERCOM
MODULE
Now configure your Welcome outdoor station.
For the
INTERCOM
MODULE there are three potentiometers on the back side of the outdoor station,
there are important. Here you set the SIP ID of the
call buttons.
The left potentiometer indicates the address of the outdoor station.
The middle and right potentiometer indicate the address of the upper bell button of the outdoor
station. The underlying bell buttons are numbered from top to bottom in order. Thus, for this example,
a SIP ID for the upper bell button arises as follows.
1.
Address of the outdoor station (Y) = 1
2.
Now 6 zeros are added internally
3.
Address of the indoor station composed of tens place (Z) and one place (E).
Y000000ZE = 100000001
For the underlying bell button it then behaves as follows:
Y01 = 100000002
Y02 = 100000003
Figure 32: INTERCOMMODULE configuration Welcome