background image

47 

 

J16  H5.2mm 

J15  H9.2mm 

 

Содержание e-medic SILENCE TP 7

Страница 1: ......

Страница 2: ...ii Version Change History Date Version Description Remark 2018 8 16 1 0 First release Cosa...

Страница 3: ...emi Conductor Co Ltd C T is a trademark of Chips and Technologies Inc UMC is a trademark of United Microelectronics Corporation ITE is a trademark of Integrated Technology Express Inc Intel is a trade...

Страница 4: ...harmful interference to radio or television reception this can be determined by turning the equipment on and off If interference is occurring the user is encouraged to try to correct the interference...

Страница 5: ...amine the contents to see if there are damages to the unit and if all accessories are present Setting up Please read this manual carefully and remember to keep this manual for future reference Safety...

Страница 6: ...recommended by the manufacturer Electrical and Power Source Related 1 This medical panel PC unit must operate on a power source as shown on the specification label If you are not sure what type of pow...

Страница 7: ...anel PC unit 3 Having liquids seep in or inserting objects into the unit may result in electric shocks from taking and or short circuiting the internal parts 4 Do not place the medical panel PC unit i...

Страница 8: ...ic switch Each circuit represents a bit binary digit of information so that when the circuit is on it represents a 1 and when off it represents a 0 in positive logic representation The circuits are ar...

Страница 9: ...ccur turn the power source off and unplug the unit Then contact a qualified service technician a A liquid was spilled on the unit or objects have fallen into the unit b The unit is soaked with liquids...

Страница 10: ...the mark left must be disposed of separately from normal household waste This includes monitors and electrical accessories such as signal cables or power cords When you need to dispose of your display...

Страница 11: ...l electrical equipment Part 1 General requirements for safety EN 60601 1 1 IEC 60601 1 1 Medical electrical equipment Part 1 1 General requirements for safety Collateral standard Safety requirements f...

Страница 12: ...comply with the system standard IEC 60601 1 1 Everybody who connects additional equipment to the signal input part or signal output part configures a medical system and is therefore responsible that t...

Страница 13: ...pose of used batteries according to the instructions If battery pack is not used for 1 month it is recommended to remove the battery pack from equipment IEC 704 1 1982 is no more than 70dB A A Groundi...

Страница 14: ...es 3 Specifications 4 electromagnetic emissions 7 electromagnetic immunity 9 Immunity 10 Cleaning Disinfecting 12 Getting Started 13 System Set Up 13 Dimension 14 System View 15 Disconnect Device 20 B...

Страница 15: ...ilence TP7 includes all the features of a powerful computer into a slim and attractive chassis Resolutions Integrating with high brightness LCD is easier to analyze DICOM image The e medic Silence TP7...

Страница 16: ...ake sure that the following items have been shipped The e medicTM Silence TP7 Medical Panel PC unit User s manual chipset drivers Power Adapter x 1 Mf Sinpro type model HPU101 107 Power cord Hospital...

Страница 17: ...ptional 2 5 HDD driver bay with doggy door Internal expansion support M 2 E key x 1 mini PCIe x 1 Easy wipe surfaces with no internal corners IP65 at front side Fanless solution USB3 1 gen2 x 2 option...

Страница 18: ...5W max Disk Drive Space M 2 Type SATA SSD 2260 slot interface x 1 SSD 3 3Vdc 1 5A max Optional door 5Vdc 1 0A max Expansion One Mini PCIe slot total loaded 2 277W One M 2 Type E slot total loaded 2 27...

Страница 19: ...olated 4KV RS 232 1 RS 232 422 485 1 The isolated ports verified through Dielectric test 4000Vac only PCI E x 4 slot 1 USB 3 0 port 4 Side USB 2 0 port 2 DC in w lock function 1 Gigabit LAN RJ 45 Conn...

Страница 20: ...MFR Sinpro Type HPU101 107 Input Rating AC 100 240 V 1 2 0 5A 47 63 Hz Output Rating DC 18V 5 55A MTBF 100 000 hrs operation at 25 C Classification Power by Class I certified po wer adapter No applie...

Страница 21: ...ation 186 1060 hPa Storage 186 1060 hPa Transportation EMI Safety CE FCC VCCI Class B UL 60601 1 EN 60601 1 IP Front IP65 Rear IPX0 22 IPX1 22 Noise Fanless Touch Screen P cap touch Type Full flat pro...

Страница 22: ...ration distances between portable and mobile RF communications equipment and the model e medicTM Silence TP7 The model e medicTM Silence TP7 is intended for use in an electro magnetic environment in w...

Страница 23: ...agnetic environment specified below The customer or the user of the model e medicTM Silnce TP7 should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level...

Страница 24: ...ded that the model e medicTM Silence TP7 be powe red from an uninter ruptible power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30 A m 30 A m Power frequency magnetic fie...

Страница 25: ...marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by abs...

Страница 26: ...de vice disconnect the unit from the power source Contact your Biomed regarding the continued safety of the unit before placing it back in operation Do not spray cleaning agent on the chassis Do not...

Страница 27: ...onnector on the rear of the system and the plug to an electrical outlet 4 Waiting for 3 seconds then press the power switch on the front panel of the system once to turn on the system power 5 If neces...

Страница 28: ...on Touch screen bottom side from left to right front view 1 LCD on off with LED status indicator LCD ON dark LCD OFF Green 2 Clean me with LED status indicator ON Green OFF dark a Keep on contacting...

Страница 29: ...release after 60 seconds 3 Fn key selection with LED status indicator ON Green DICOM mode OFF dark PC mode a Keep on contacting 5 seconds to active DICOM mode b keep contacting 5 seconds to release D...

Страница 30: ...17 I O parts...

Страница 31: ...18 I O parts W ISO...

Страница 32: ...19 I O parts W USB 3 1 gen2...

Страница 33: ...20 Disconnect Device Unplug the power cord from the power adapter jack to disconnect the device Turn off the system Turning off e medic Silence TP 7 properly is important for system reliability...

Страница 34: ...ately activated Pressing the Del key immediately allows you to enter the Setup utility If you are a little bit late pressing the Del key POST Power On Self Test will continue with its test routines th...

Страница 35: ...22 Main...

Страница 36: ...n the BIOS information Embedded controller information and Battery information System Date Set the system date Use the Tab key to switch between data elements System Time Set the system time Use the T...

Страница 37: ...time Increase minute s CPU Configuration CPU Configuration Parameters Hyper Threading Enabled for Windows XP and Linux OS optimized for Hyper Threading Technology and Disabled for other OS OS not opt...

Страница 38: ...arameters Driver Health Provides Health Status for the Drivers Controllers Trusted Computing Trusted Computing settings Configuration Enables or disables BIOS support for security device O S will not...

Страница 39: ...ure Erase module Simulated Causes the module to show the flow without actually erasing SSD Real Causes the module to erase SSD Force Secure Erase Force Secure Erase on next boot Info Report Configurat...

Страница 40: ...SB keyboard legacy support for non USB aware OSes USB hardware delays and time outs USB Transfer Time out The Time out value for control Bulk and Interrupt transfers Device reset time out USB mass sto...

Страница 41: ...xternal Gfx Card on PEG and PCH PCIE Ports Primary Display Select which of IGFX PEG PCI Graphics device should be Primary Display or Select SG for Switchable GFX Internal Graphics Keep IGFX enabled ba...

Страница 42: ...disable Compliance Mode Default is FALSE to not disable Compliance Mode Set TRUE to disable Compliance Mode xDCI Support Enable Disable xDCI USB OTG Device USB Port Disable Override Selectively Enable...

Страница 43: ...curity Configuration for selected drive Secure Boot menu Secure Boot Secure Boot can be enabled if 1 System running in User mode with enrolled Platform key PK 2 CSM function is disabled Secure Boot Mo...

Страница 44: ...PXE Boot UEFI PXE Network Boot Enable Disable Boot Option 1 Sets the system boot order Boot Option 2 Sets the system boot order Fast Boot Enables or disables boot with initialization of a minimal set...

Страница 45: ...Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving the changes Save Changes Save the changes done so far to any of setup opti...

Страница 46: ...33 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options...

Страница 47: ......

Страница 48: ...rmal Open 1 2 default CMOS Clear 2 3 JP2 RTC Register Clear Selection Description Jumper Setting Normal Open default RTC Register Clear 1 2 Connector Definition PJ1 PJ2 PJ3 Battery Connector Pin Signa...

Страница 49: ...36 PJ4 HDD Power Connector Pin Signal Description 1 12VS 2 GND 3 GND 4 5VS PJ5 Power Input Connector Pin Signal Description 1 GND 2 GND 3 DC In 4 DC In...

Страница 50: ...37 PJ6 Power Jack Pin Signal Description 1 DC In 2 DC In 3 GND 4 GND PJ7 5V 1A DC OUT Pin Signal Description 1 5VS 2 GND J1 LCD Inverter Wafer Header...

Страница 51: ...S Interface Pin Signal Description Pin Signal Description 39 GND 40 GND 37 Ground 38 GND 35 A_TXD3 36 B_TXD3 33 A_TXD3 34 B_TXD3 31 GND 32 GND 29 A_CLK 30 B_CLK 27 A_CLK 28 B_CLK 25 GND 26 GND 23 A_TX...

Страница 52: ...8 GND 5 GND 6 GND 3 LVDS PWR 4 LVDS PWR 1 LVDS PWR 2 LVDS PWR J3 J4 Internal USB 2 0 Pin Header Pin Signal Description 1 5VSB 2 5VSB 3 Data 4 Data 5 GND 6 GND J5 Internal USB 2 0 Pin Header for PCT To...

Страница 53: ...2 0 Pin Header for Webcam Pin Signal Description 1 5VSB 2 5VSB 3 Data 4 Data 5 GND 6 GND J7 Internal COM1 Serial Port Pin Signal Description RS 232 RS 422 RS 485 1 232_DCD TX D DATA 2 232_DSR 3 232_SI...

Страница 54: ...VS J8 Internal COM2 Serial Port Pin Signal Description Pin Signal Description 2 232_DSR 1 232_DCD 4 232_RTS 3 232_SIN 6 232_CTS 5 232_SOUT 8 232_RI 7 232_DTR 10 NA 5VS 9 GND J9 Mini PCI Express Pin Si...

Страница 55: ...PERn0 24 3 3VSB 25 PERp0 26 GND 27 GND 28 1 5VS 29 GND 30 SMB_CLK 31 PETn0 32 SMB_DATA 33 PETp0 34 GND 35 GND 36 USB_D 37 GND 38 USB_D 39 3 3VSB 40 GND 41 3 3VSB 42 Reserved 43 GND 44 Reserved 45 NC C...

Страница 56: ...round S6 SATA_Rx P6 Ground S7 Ground P7 5VS P8 5VS P9 5VS P10 Ground P11 Reserved P12 Ground P13 12VS P14 12VS P15 12VS J11 80 Port Pin Signal Description Pin Signal Description 1 LPC_AD0 2 5VS 3 LPC_...

Страница 57: ...6 NA 27 NA 28 NA 29 NA 30 NA 31 NA 32 NC 33 GND 34 NC 35 PETP0 36 NC 37 PETN0 38 CLINK Reset 39 GND 40 CLINK DATA 41 PERP0 42 CLINK CLK 43 PERN0 44 RSVD 45 GND 46 RSVD 47 REFCLKP0 48 RSVD 49 REFCLKN0...

Страница 58: ...12 3 3VS 13 NC 14 3 3VS 15 GND 16 3 3VS 17 NC 18 3 3VS 19 NC 20 NC 21 GND 22 NC 23 NC 24 NC 25 NC 26 NC 27 GND 28 NC 29 NC 30 NC 31 NC 32 NC 33 GND 34 NC 35 NC 36 NC 37 NC 38 M2_DVESLP 39 GND 40 NC 41...

Страница 59: ...71 GND 72 3 3VS 73 GND 74 3 3VS 75 GND J14 TPM ID 394 Pin Signal Description Pin Signal Description 16 3 3VSB 15 SUS_STAT 14 SMB DATA 13 GND 12 SMB CLK 11 Debug CLK 10 CLKRUN 9 LPC Frame 8 5VSB 7 LPC...

Страница 60: ...47 J16 H5 2mm J15 H9 2mm...

Страница 61: ...D RXP1 6 SMBDATA RSVD 22 GND RXN1 7 GND RSVD 23 TXP2 GND 8 3 3VS_PCIE RSVD 24 TXN2 GND 9 RSVD 3 3VS_PCIE 25 GND RXP2 10 3 3VSB 3 3VS_PCIE 26 GND RXN2 11 PCIE_WAKE PLT_RST 27 TXP3 GND 12 PCIE_CLKRQ GND...

Страница 62: ...on 1 CS0 5 MOSI 2 MISO 6 SCLK 3 WP 7 HOLD 4 GND 8 3 3VS J20 CAP Front Bezel Button Pin Signal Description 1 5VS_ALWAYS 2 3 3V_ALWAYS 3 KP_SCL 4 KP_SDA 5 NC 6 NC 7 RESERVED 8 GND 9 GND J21 J35 Reading...

Страница 63: ...ription 1 MIC_R MIC_L 2 GND J23 J24 LEFT RIGHT CH for Speaker Pin Signal Description J23 LEFT CH J24 RIGHT CH 1 LOUT ROUT 2 LOUT ROUT J25 J26 External RJ45 Ethernet Port Activity Link LED Status Descr...

Страница 64: ...ata1 11 Data2 3 Data1 12 Data2 4 GND 13 GND 5 SSRX1 14 SSRX2 6 SSRX1 15 SSRX2 7 GND 16 GND 8 SSTX1 17 SSTX2 9 SSTX1 18 SSTX2 J29 J30 DisplayPort Interface Pin Signal Description Pin Signal Description...

Страница 65: ...External Audio Phone Jack Audio Jack Signal Description J31 Line Out stereo Green J32 Microphone stereo Pink J33 Reset Connector Pin Signal Description 1 SYS_RESET 2 GND J34 Power Switch connect Pin...

Страница 66: ...3 3VSB LPC_AD1 4 PCIE1_RXP PCIE2_RXP 20 3 3VSB LPC_AD2 5 GND GND 21 5VSB LPC_AD3 6 PCIE1_TXN PCIE2_TXN 22 5VSB USB_OC 7 PCIE1_TXP PCIE2_TXP 23 5VSB COM_GPO1 8 GND GND 24 5VSB COM_GPO2 9 PCIE1_CLKN US...

Страница 67: ...scharging Current Max 10 A The End of Charge Condition 12 6 V Discharge Protection 16 0 5 A Charge Protection 6 0 5 A Self discharge Rate 1mA Dimensions 140mm x 89mm x 19 7mm Weight 470g Ambient Tempe...

Страница 68: ...Full Charge Status Full Charge Battery in Charge Status Charging Battery in Discharge Status Discharge Nonworking Battery Status Stand by Low power Battery Status Low Battery No battery or Battery in...

Страница 69: ...56 Battery Installation 1 Push the button 2 Open the battery cover 3 Check connector position of battery as shown above 4 Insert the battery 3 4 1 2...

Страница 70: ...eed the maintenance or are bey ond repair we strongly recommended that you should inform us as soon as possible for the suitable solution For the compu ters that are no longer useful or work well plea...