31
Data transfer modes
The HVA built-in memory can save up to 50 reports and 40 test sequences. Data
storage location and transfer capability depends on the configuration of the
communication port
.
Configuration Characteristics
RS232
(standard)
•
During testing, RS232 cables are
not
connected to communication
port
•
Test sequences are directly saved to HVA memory
•
New reports are directly saved to HVA memory
•
All test sequences and reports saved in HVA memory can be
transferred to the linked PC once the HVA Control Center CD has
been installed
USB flash
adapter
(optional)
•
During testing, USB adapter and stick are connected to
communication port
•
When connected, left hand corner of main menu displays “USB”
•
Test sequences are directly saved to HVA memory
•
New reports are directly saved to USB stick inserted in adapter
•
Reports saved on the USB stick can be retrieved and viewed on the
HVA display:
•
All reports saved in HVA memory can be transferred to the linked
USB stick:
Main Menu
USB - Main Menu - HVA 120
Use Last Test Seq.?
3.0kV Maint. C. HYBR (T)
Start a New Test
Manual Mode
Reports & Setup
13.3.2009 10:23
Reports &Setup
Reports & Setup
View Reports (2)
Store Rep. to USB
Edit Auto Test Seq.
Instrument Settings
Display Contrast 4
Service
USB
USB Memory Stick
attached
MAIN
No Reports to Store
OK
Main Menu
USB - Main Menu - HVA 120
Use Last Test Seq.?
3.0kV Maint. C. HYBR (T)
Start a New Test
Manual Mode
Reports & Setup
13.3.2009 10:23
Reports &Setup
Reports & Setup
View Reports (2)
Store Rep. to USB
Edit Auto Test Seq.
Instrument Settings
Display Contrast 4
Service
USB
MAIN
View Report 2/2.
ALPHA
ALPHA 2
MAIN
SELECT DEL CLR-ALL
1/3
Содержание HVA34
Страница 2: ...1 Introduction 2 DHV0078 b2 EN b2 electronic GmbH...
Страница 11: ...2 Safety b2 electronic GmbH DHV0078 b2 EN 11...
Страница 22: ...4 Design and Construction 22 DHV0078 b2 EN b2 electronic GmbH Switches and controls Front panel HVA34...
Страница 33: ...5 Test Procedure b2 electronic GmbH DHV0078 b2 EN 33 Connection diagram vacuum bottle test...
Страница 47: ...5 Test Procedure b2 electronic GmbH DHV0078 b2 EN 47 5 5 Discharge Status...
Страница 62: ...11 Declaration of Conformity 62 DHV0078 b2 EN b2 electronic GmbH 11 Declaration of Conformity HVA34...
Страница 63: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 63 HVA30 5...
Страница 64: ...11 Declaration of Conformity 64 DHV0078 b2 EN b2 electronic GmbH HVA30 7 HVA40 5 HVA54 3...
Страница 65: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 65 HVA54 5...
Страница 66: ...11 Declaration of Conformity 66 DHV0078 b2 EN b2 electronic GmbH HVA60...
Страница 67: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 67 HVA68 2...
Страница 68: ...11 Declaration of Conformity 68 DHV0078 b2 EN b2 electronic GmbH HVA90 HVA94...
Страница 69: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 69 HVA120...