Combustible Surfaces
Clearances to combustible surfaces must be in accordance with AS/NZ 5601-
Gas Installations
,
clause
5.12.4.5.
Install on a flat/level, solid, fire resistance floor. Where the floor is not fire resistant, a fire resistant
material shall be put under the appliance which shall have a fire resistance rating at least equal to that of
10mm millboard. The material shall extend at least 50mm beyond the edge of the appliance.
Leave a clearance of at least 200mm between the appliance and any combustible surface.
Leave clearance of at least 500mm from the front of the noodle cooker for services.
Plinth Mount Models
To plinth mount remove the legs and sit the unit on a concrete slab which should be the width of the
appliance and 700mm deep. The height of the slab is determined by the installer.
Gas Connection
The gas connection is male ¾” BSP and is situated at the rear of the appliance below the main body frame.
The inlet is to the ¾” pipe inlet located at the rear of the appliance.
This appliance is available in models for fixed installation.
The appliance can be connected with rigid pipe as specified in AS/NZ 5601. For fixed installation models we
recommend connection with 20mm copper tube and a certified isolating ball valve.
BEFORE CONNECTING NEW PIPE TO THIS APPLIANCE, THE PIPE MUST BE BLOWN OUT
THOROUGHLY TO REMOVE ALL FOREIGN MATERIAL. FOREIGN MATERIAL IN THE BURNER AND
GAS CONTROLS WILL CAUSE IMPROPER AND DANGEROUS OPERATION.
Connect to gas.
Pressure Test Point
All appliances that are dispatched from our factory are tested and adjusted according to the specifications for
the required gas type. The regulator may require adjustment to achieve required gas pressure.
Check the burner pressure at the test point on the regulator. The test point pressure should be adjusted to
1.00 kPa
– Natural gas or 2.60 kPa – LPG with the burners operating at maximum.
Water Connection
The water connection is 15mm copper and is situated at the rear of the appliance below the main
body frame. The number of water inlets varies to client
’s particular needs. Water isolation valves are fitted
to all water inlets. Ensure water is flushed through before final connection.
Water waste outlet is located on the left hand side of the waste gutter of the appliance (50mm connection).
The water inlets and water drains should be connected with rigid copper pipes. We do not recommend the
usage of plastic/PVC piping for connection of waste outlet.
Burner Adjustment
The burners do not require any adjustments.
Note:
If any problems are experienced in maintaining the burners, your local service agent should be
connected.