background image

 

 

6  

  

IMPORTANT WARNINGS  

 

 

  

ENSURE   ANY   TRANSIT   PROTECTION   IS   REMOVED   BEFORE 

 

INSTALLING THE APPLIANCE. 

 

THIS APPLIANCE IS NOT INTENDED TO BE INSTALLED OR USED IN A MARINE 
ENVIRONMENT. ENSURE APPLIANCE IS INSTALLED IN A STABLE POSITION.

 

INSTALATION AND SERVICING SHALL BE CARRIED OUT ONLY BY 
AUTHORISED PERSONNEL. 

 

 

 

FAILURE TO DO SO WILL VOID B&S WARRANTY AND MAY RESULT IN DAMAGE TO EQUIPMENT OR INJURY 

TO PERSONNEL. 

 

Please  note  that  checking  and  adjusting  of  burner  pressures  on  commercial  catering  appliances  is  an  obligation  of 

gasfitters. 

 
The relevant  legislation  is as follows from the 

Plumbing Regulations  2008

 administered by the 

Victorian Building 

Authority: 

 Gas fitting work defined

 

(1)  Gas  fitting  work  is  the  construction,  installation,  replacement,  repair,  alteration,  maintenance,  testing  or 

commissioning

 of any pipe, 

appliance

, flue, fitting, apparatus, control or other item that is involved with the 

supply or use of gas and that is fitted downstream of the outlet of a customer billing meter or a consumer's gas 
storage container 

  
As per 

AS/NZS5601.1

, clause 6.11.1, this gas appliance must be 

commissioned

 by a suitably authorized person who; 

  

(a)  Installed the appliance when gas is available at the time of installation; or 
(b)  Makes gas available to the appliance if gas was not available at the time of installation 

  
As per 

AS/NZS5601.1

, clause 6.11.3, the commissioning of this appliance shall take 

full account of special design 

features, the manufacturer’s instructions and the appliance safety requirements

  
As per 

AS/NZS5601.1

, clause 6.11.4, the commission of this appliance shall include all of the following; 

  

(a) 

Testing and purging

 of the appliance and installation as appropriate. 

(b)  Checks to ensure the appliance is in 

safe working order

(c)  Ignition  of  each 

burner

  of  the  appliance  and  where  necessary  adjustment,  in  accordance  with  the 

manufacturer’s instructions.

 

(d)  Testing of 

flue

 performance. 

(e)  Testing of all 

safety devices

 for correct operation. 

(f) 

Instruction

  of  the  consumer,  where  available,  on  the  safe  and  correct  operation  of  the  appliance  and  any 

auxiliary equipment. 

(g)  Handing of the appliance 

operating instructions

 to the consumer, or if the consumer is not present, leaving 

the instructions in a suitable location on the premises. 

 

Installation Instructions  

  

Regulations  

This appliance shall be installed only by authorized persons and in accordance with the ma

nufacturer’s installation 

instructions, local gas fitting regulations, municipal building codes, AS 5601 

– Gas Installations and any other statutory 

regulations.  

 

 

Содержание DSK Series

Страница 1: ... Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any means is strictly forbidden unless agreed to in writing by the manufacturer Owing to continual product development and improvements to its products B S Commercial Kitchens Pty Ltd reserves the right to change t...

Страница 2: ...structions 6 Regulations 6 Data Label 7 Ventilation 7 Combustible Surfaces 7 Gas Connection 7 Water and Drainage Connection 7 Before Leaving 8 Operating Instructions 8 Shutdown Procedure 9 Maintenance Schedule 9 SERVICING INSTRUCTIONS 10 Abnormal Operation 10 Gaining Access to Gas System 10 Removal of Burner for Service 10 Pilot and Flame Safeguard 10 Over Temperature Cut Out Device on D3 Unit 10 ...

Страница 3: ...3 STANDARD WARRANTY CONDITIONS 13 ...

Страница 4: ...ormance servicing and installation of the appliance please contact your B S dealer immediately In most instances a phone call could answer your question Table 1 Nominal Terminal Input Rates Injector Size Orifices Gas Type Injector Size Main Burner Pilot mm Gas Test Point Pressure kPa MJ h Rating per Burner Total Nominal Gas Consumption DS 2 3 LPG 2 00 1 00 2 60 150 150 MJ h DS 2 3 NG 3 10 1 55 1 0...

Страница 5: ...nnection Position from Floor mm Position from Rear of Appliance mm Position from LHS RHS edge of Appliance mm Water Inlet WI nonreturn valve 120 5 620 5 125 5 LHS Gas Inlet GI male BSP 145 5 670 5 210 5 LHS Tank drain D1 1 male BSP 110 5 390 5 245 5 RHS Waste D2 1 BSP 120 5 400 5 85 5 LHS ...

Страница 6: ...ce when gas is available at the time of installation or b Makes gas available to the appliance if gas was not available at the time of installation As per AS NZS5601 1 clause 6 11 3 the commissioning of this appliance shall take full account of special design features the manufacturer s instructions and the appliance safety requirements As per AS NZS5601 1 clause 6 11 4 the commission of this appl...

Страница 7: ...rfaces Clearances to combustible surfaces must be in accordance with AS NZS 5601 1 Gas Installations clause 5 12 4 5 Install on a flat solid fire proof base Leave at least 200mm between the appliance and the side and rear walls The Steamer shall be installed so that a clear space of 200mm is maintained between the sides of the steamer and any other appliance No combustible material shall be locate...

Страница 8: ...n the control panel door is opened 5 Make sure pilot burns well and then switch on the burners by rotating the relevant ball valve anit clockwise to the ON position as indicated The left Ball Valve operates the left hand side burner whilst the right Ball Valve operates the two right hand side burners 6 If the burner extinguishes wait at least 5 minutes to relight and repeat from step2 to step 5 7 ...

Страница 9: ...rials Ensure the primary water drain and steam outlet are cleared of any food stuffs Weekly Checks Service Ensure water tank is emptied on a weekly basis Water tank drain valve is accessed from underneath the appliance and turning gate valve handle anti clockwise located on the right hand side below main water tank Turn drain valve clockwise to stop Inspect burner area and ensure pilot is in posit...

Страница 10: ...assemble the panel in the reverse order Removal of Burner for Service Follow procedure described under GAINING ACCESS TO GAS SYSTEM Remove burner by undoing bolt assembly located on the burner support bracket Gently lift burner upwards slightly and pull burner outwards REASSEMBLE IN REVERSE ORDER Pilot and Flame Safeguard Access to the D3 unit pilot assembly is gained by removing the front control...

Страница 11: ... Fax 61 3 9469 4504 E mail info bscommercialkitchens com Adjustments Pilot 1 Remove front panel as described under GAINING ACCESS TO GAS CONTROLS 2 To increase gas pressure to pilot turn adjustment screw located at the top right hand side of the flame failure devise anti clockwise 3 To decrease gas pressure to pilot turn adjustment screw located at the top right hand side of the flame failure devi...

Страница 12: ...roubleshooting In case of difficulties or for spare parts please contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscommercialkitchens com ...

Страница 13: ...r or not a fault is caused by faulty workmanship or material or that any part is defective 6 This warranty does not apply to any loss suffered through or resulting from the non operation or the ineffective operation of the cooking appliance or any part of the cooking appliance 7 This warranty does not extend to goods and components thereof manufactured either entirely or substantially of glass or ...

Отзывы: