Help in the event of problems
Temperature display does not
light up with unit door closed
Temperature display illuminates,
but food is not kept sufficiently
cold
Cause
Action
Power plug is unplugged.
Plug the power plug into the electrical
outlet.
Power plug is damaged; a wire
is broken, for example (can also
occur without external dam-
age).
Have power plug replaced by a facility
authorized to carry out repairs.
Customer-accessible fuse
(household fuse) is defective.
Check the customer-accessible fuse
and replace it if necessary.
The unit electronic system is
defective.
Notify a facility authorized to carry out
repairs.
Cause
Action
The setpoint temperature is set
too high.
Set a lower setpoint temperature
Subsection "Setting the setpoint
temperature" on Page 14.
Ventilation slits blocked.
Remove objects in front of the ventila-
tion of the refrigeration unit.
High ambient temperature.
Move the unit to a cooler location.
– or –
Have a refrigeration technician
change the refrigeration parameters
of the temperature regulator.
Evaporator in unit covered with
ice.
Defrost the unit.
Subsection "Defrosting the unit
manually" on Page 14.
Seal on unit door defective.
Notify a facility authorized to carry out
repairs.
Air baffle not mounted on inside
of door.
Mount air baffle.
Subsection "Unhooking air baffle"
on Page 28.
Convection revision panel not
mounted.
Mount convection revision panel.