background image

 

 

          

 

 

 

 

B METERS srl 

Cod. Fisc. e  P. IVA n°: IT01750340307 

Tel. +39.0432.931415 - 931418 

Via Friuli n°3  

Cap. Soc. € 500.000,00 i.v. 

Fax +39.0432.992661                       

33050 GONARS (UD) 

Reg. Impr. di UD n° Iscr.  01750340307 

  www.bmeters.com 

ITALY 

 

[email protected] 

 

The IWM-PL3 and IWM-PL4 modules are connected as follows: 

1)

 

Ground (

BROWN)

 wire connected to the negative reference (Ground) of the output device that 

reads the pulses. PLCs usually have opto-isolated inputs therefore sharing the masses does not 
create anomalous currents. 

2)

 

Pulse output wire (

WHITE, YELLOW AND GREEN

) connected to the input of the device that reads 

the pulses (PLC for example). Please note that this input must accept an NPN polarized Open 
collector output with a voltage not exceeding 30V. 

Sometimes it is necessary to connect the output of the IWM-PL3 or PL4 device with a device that only 
accepts "clean" contacts. The clean contacts have thin name because they are not related to the mass 
(NPN) or to the supply voltage (PNP). In this case, to make the two devices "talk" it is necessary to insert an 
interface relay between the output and the input. 
The principle connection scheme is as follows: 

 

 

 

Содержание IWM-PL4

Страница 1: ...dei dati di lettura e l assenza di eventuali allarmi Per le istruzioni di configurazione complete si rimanda alla documentazione del software Per una corretta installazione del modulo sul contatore ne...

Страница 2: ...o IWM PL3 e IWM PL4 della B METERS forniscono delle uscite di tipo Open Collector OC polarizzate di tipo NPN non forniscono un contatto pulito Lo schema di riferimento il seguente Dalla figura si vede...

Страница 3: ...ipo Open collector NO CONTATTO PULITO o DRY CONTACT 2 La tensione applicata al contatto sia inferiore a 30V Questa tensione in pratica coincide con la tensione di alimentazione del dispositivo di lett...

Страница 4: ...le masse non crea correnti anomale 2 Filo di uscita degli impulsi BIANCO GIALLO E VERDE collegato all ingresso del dispositivo che legge gli impulsi PLC ad esempio Si ricorda che questo ingresso devo...

Страница 5: ...neralmente indicati dalla scheda tecnica del rel Procedere dunque nel seguente modo 1 Collegare l ingresso del rel bobina di eccitazione all uscita del IWM PL3 o IWM PL4 come da schema Un terminale de...

Страница 6: ...meter it is necessary to insert the screw and apply the sticker seal in the point shown in the picture 4 Step 1 Step 2 Step 3 Step 4 Safety During the installation process handle the device with care...

Страница 7: ...lse emitter IWM PL3 PL4 modules with inductive principle provide polarized Open Collector OC NPN type outputs they do not provide a clean contact The reference scheme is the following The figure shows...

Страница 8: ...OUR OUTPUT IS 1 Open collector type NO CLEAN CONTACT or DRY CONTACT 2 The voltage applied to the contact is less than 30V This voltage coincides with the supply voltage of the external reading device...