ver.1.3
Safety
•
During the installation process, handle the device with care, don’t crush, don’t
bent, don’t exposure to electrostatic discharges which could damage permanently
the device, do not install close to heat sources (radiators, conditioners, convectors
etc..).
•
The
IWM-LR4
module doesn’t contain hazardous materials in accordance with
European directives 91/157/EEC, 93/86/EEC, and 2002/95/EC(RoHS). The device
requires specific disposal on the end of its lifetime. Recycling is mandatory or
recommended following the Directive RAEE 2012/19/UE inside European Union
region, or anyway dispose in accordance with local laws and regulations. Do not
burn or undergo to high temperatures.
•
The
IWM-LR4
works reliably in the environmental conditions specified in
this manual. Any unauthorized intervention and/or modification may cause
malfunctions or total damaging of the product.
Warranty
The warranty period is set at 24 (twenty-four) months from the date of the shipping of the
material. Warranty is against defects in materials or workmanship when the product is
properly used and maintained in normal efficiency. This Warranty is valid and enforceable
in the country where the product was purchased. In the event that the product has been
purchased in a country of the European Union, the warranty is still valid in all countries
of the Community.
To obtain warranty service, it is requested to comply with the following clauses:
1.
Products must be delivered for repair at the expense of the customer.
2.
The product warranty will be subject to the exhibition of a tax document (receipt,
receipt or bill of sale), which attests to the date of purchase of the product.
3.
The repair will not affect the original date of expiration of the warranty and will not
involve the renewal or extension thereof.
4.
If at the time of the repair, the product has not any defect, it will be charged the
costs of the technical analysis.
5.
The warranty is void if the failure was due to: impacts, falls, misuse or abuse of the
product, use of non-original batteries, accidents, product alteration, replacement/
detachment of seals and/or product tampering. The same also does not cover
damage caused during transport if packages used are unsuitable.
6.
The warranty is not covering the battery of the product
7.
The warranty does not cover the inability to use the product, other costs incidental
or consequential damages or other expenses incurred by the purchaser.
8.
The warranty doesn’t cover damage to the product caused by usage in any other
way than described in this manual.
Support on the products
If the product needs to be sent to the technical assistance, contact your dealer or contact
the B METERS After sales service at
.
Declaration of Conformity
Hereby, B METERS, declares that this
IWM-LR4
is in compliance with the essential
requirements and other relevant provisions of Directive 2014/53/EU.
The complete declaration can be downloaded from the official website
www.bmeters.com
.
Contact Info
B METERS Srl
V
ia Friuli 3
Gonars (UD) - 33050
Italia
Tel: +39 0432931415
Fax: +39 0432992661
E-Mail (sales/information): [email protected]
E-Mail (technical support): [email protected]
Web: www.bmeters.com
Quick User Guide – IWM-LR4_QUG
Product description
The
IWM-LR4
module is a device that allows to transmit the reading data detected by
WDE-K50 water meters manufactured by B METERS.
The device is already preconfigured in OTAA mode with preset keys. The keys (DevEUI,
AppEUI and AppKey) are provided by BMETERS. For various needs, the modules can be
configured in Activation By Personalization (ABP) mode via Android App. The application
allows you to configure the module by choosing the different operating options. Please
refer to the configuration app manual for a detailed description of the configuration
features and options available.
Package Content
•
IWM-LR4
module with aluminum sticker already applied
•
Mounting screw
•
Anti-tampering sticker
•
Installation guide
Technical data
•
Working temperature: From +1°C to +55 °C
•
Power supply voltage: Lithium battery 3V Li-SOCI2 – 2,4 Ah*
•
Maximum battery duration: 10 years**
•
Radio interface: LoRaWAN @868MHz [<25mW]
•
Configuration: by using Android App + NFC Device
•
Protection level: IP68***
•
Transmission range: up to 5 Km****
•
Dimensions: (l x d x h): 100 x 100 x 57 mm
•
Weight: 167g
* Batteries are not replaceable, DO NOT ATTEMPT TO REPLEACE. Any attempt will void
the warranty, moreover will irreversibly damage the device.
** The battery life strongly depends on the working time window, set during the
configuration process, and on the environmental conditions. Estimation of the battery
life is given by the configuration software.
***IP68: maximum 24 hours of continuous submersion at 1 m depth
****Under optimal propagation conditions, the radio range depends on physical
conditions (building constructions, climatic conditions, …) where propagation of the radio
signal can therefore vary.
Installation
The installation of the
IWM-LR4
module is allowed on the WDE-K50 meters only (from
DN50 to DN200).
It is recommended to install the
IWM-LR4
module away from metal objects or any
potential radio shielding, in a place protected from tampering.
Provision the network server in which you want to integrate the sensor (AppEUI) and
provide the application server with the unique DevEUI and AppKey keys. The installer has
the task of checking the propagation conditions of the radio signal during installation.
Commissioning
Make sure that you have respected the installation conditions described above and that
the module is positioned within the operating range of the LoRa gateway installed.
Remove the aluminum sticker applied on the bottom of the module and mount it on
the meter as shown in the pictures. It is necessary to combine the hooks of the meter
with the ones on the module [1]. With one hand keep the meter steady, with the other
hand push the module gently towards the dial [2] and pull it in the direction shown by
the arrow [3/4]. Proceed with the configuration of the K index (10 for all diameters up to
DN125 included or 100 for diameters DN150 and DN200). Before proceeding with this, it
is necessary to read the module to avoid incorrect LORA keys writing.
To initialize the module and send joining requests to the desired network server, it is
necessary to let the inductive index of the dial rotate for +/-5 revolutions (on the
WDE-K50 models, this corresponds to +/- 50 or 500 liters, depending on the K value set).
Verify then that the module has joined the network server in the next few moments.
Configuration by using Android App + NFC Device (for ABP mode or parameter modification)
:
to initialize the configuration process, place the NFC antenna of the android device near
the module as shown in the picture. For the complete configuration instructions, please
refer to the app manual.
To avoid possible frauds on the module, it is recommended to tighten the mounting
screw supplied and apply the adhesive seal.
IWM-LR4
LORAWAN radio module for B METERS water meters
Step 1
Step 2
Step 3
IWM-LR4
installation:
IWM-LR4
configuration / activation:
IWM-LR4
adhesive seal mounting:
Configuration via NFC (optional)
Radio activation after +/- 5 index
revolutions
Before installing the
IWM-LR4
:
Protective seal removal
NFC