28
User Manual v1.4.3
HYDRODIGIT
TRANSLATION
For deliveries to countries in the European Economic Area, the operating instructions are to be translated
into the appropriate language of user country.
Should there be any inconsistencies in the translated text, the original operating instructions (Italian) are to
be consulted or the manufacturer should be contacted.
Model
HYDRODIGIT
Measuring class/Permitted installation
R400H, R160V
R250H, R160V
R160H, R160V
Depending on the order
Flow detection technology
Turbine reading by inductive system
Temperature class
T50, cold water, T30-90 hot water
Display
LCD, 8 icons
Protection class
IP68*
Local Interface
Optical interface IR IEC 62056-21
Radio standard
Depending on the version:
- Wireless MBUS EN 13757-4 OMS compatible;
- COMBO - output configuration:
Wireless MBUS EN 13757-4 OMS v4;
- COMBO - output configuration: LoRaWAN;
- COMBO - output configuration:
L Wireless MBUS EN 13757-4 OMS v4;
Radio Frequency
868 MHz
Radio range / radio power
Wireless MBUS: 300 meters**
LoRaWAN: 5 Km**
Battery life
max 10 years***
*IP68: maximum 24 hours of continuous submersion at 1 m depth.
Note: in case of damage caused by involuntary impact, the meter must be replaced with a new one, to
restore the protection class.
**Under optimal propagation conditions, the radio range depends on physical conditions (building
constructions, climatic conditions, …) where propagation of the radio signal can therefore vary.
*** The battery life strongly depends on the working time window, set during the configuration process, and
on the environmental conditions. Estimation of the battery life is given by the configuration software.
TECHNICAL DATA