B medical systems MRB 3000 SDD Скачать руководство пользователя страница 7

7

2.1.1  Warnings

• Do not use the device outdoors. Current leakage or electric shock may result if the unit is exposed to

rain water.

• Before cleaning or carrying out maintenance work, always switch the device off and disconnect the mains

plug. Working on the connected appliance may cause electric shock or fire.

• During defrosting, water will leak from the unit. Collect this water so that it does not lead to a risk of

slipping for passing persons.

• Make sure that no water penetrates the ventilation slots of the unit.
• Before cleaning or carrying out maintenance work, the contents preserved in it will have to be removed

and temporarily stored in another working refrigerator.

• Make sure the condensation water is removed on a weekly basis. Increased condensation water inside

the device may lead to malfunctioning of the device.

• Inspect the unit on a regular basis for damaged parts. Only genuine spare parts may be used. Use of

any other parts may affect the performance or cause physical injury or damage to the equipment.

• The wall socket must be easily accessible.
• When disconnecting, always pull the plug and never the cable. Pulling the cord may result in electric

shock or fire by short circuit.

• These devices must only be used by adults. Do not allow children to play with the device or touch the

controls.

• Ensure that the unit is steady and perfectly straight and does not knock against anything next to it. If

the floor is not strong enough or the installation site is not adequate, this may result in injury from the
unit falling or tipping over.

• When transporting or moving the device, be aware of its weight. Do not try to move a fully loaded device.
• Ensure that the connecting cable is not squeezed or bent when the unit is being installed or moved.

Deterioration of the insulation may cause current leakage or electric shock.

• Never install the device where acid or corrosive gases are present as current leakage or electric shock

may result due to corrosion.

• Before connecting, check whether the details on the nameplate correspond to local values. Use of a

voltage or frequency other than that on the nameplate may cause fire or electric shock.

• Do not store flammable or explosive substances inside these appliances (e.g. aerosols with

flammable propellant). These may cause explosion or fire.

• Make sure that no sharp or pointed objects come into contact with the cooling system. The

cooling system contains flammable refrigerant. Both the appliance and the products stored
inside can be severely damaged if this system starts to leak.

• Do not insert metal objects such as a pin or a wire into any vent, gap or any outlet. This may cause

electric shock or injury by accidental contact with moving parts.

• Disconnect the power supply prior to any repair or maintenance in order to prevent electric shock or

injury.

• Do not touch any electrical parts (such as power supply plug) or operate switches with a wet hand. This

may cause electric shock.

• All installation work and adjustments to the refrigerator must be carried out by qualified personnel. Work

performed by persons with insufficient technical knowledge may adversely affect the performance or
cause physical injury or damage to the equipment.

• When the unit is in its final position it is important to immobilise the unit using the feet.
• It is of utmost importance that the icelining elements are in place. Make sure that all these elements are

in place before starting the unit. Never remove the icelining elements from the unit.

• Make sure that the lid is securely closed by closing the latches.
• Note that the unit may be locked using a key. Always ensure that the key is available to the user.
• Before scrapping an old unit, remove the door so that children cannot lock themselves inside while

playing.

• Before scrapping the unit, remove the lead accumulator and dispose of it separately.
• When disposing of the unit, make sure that it does not get too hot, as combustible gas would cause the

insulating foam to froth up.

• The appliances contain environmentally friendly refrigerant. Before disposing of the appliance, the

refrigeration circuit should be opened outside so that the refrigerant can escape. 
Attention: The refrigerant is flammable!

• Make your contribution to saving the environment. Bear in mind that orderly and proper disposal is

required. Packaging materials and devices are always recyclable and should be taken for recycling.

Содержание MRB 3000 SDD

Страница 1: ...820 9506 46 ed0821 MRB 3000 SDD SOLAR DIRECT DRIVE ICE LINED BLOOD STORAGE REFRIGERATOR Instructions for Use...

Страница 2: ......

Страница 3: ...certified according to the safety standard IEC 60335 1 This equipment is designed to be safe at least under the following conditions based on the IEC 60335 1 Indoor use Altitude up to 2000 m Temperat...

Страница 4: ...________________15 4 2 Opening and closing___________________________________15 4 3 Important Advice for Storage ___________________________16 4 4 Operating controls __________________________________...

Страница 5: ...5 1 Model Overview Group Model name Ice lined Blood Storage Refrigerators MRB3000SDD...

Страница 6: ...refrigerator for Solar Direct Drive without battery storage t has a bank of icelining elements installed inside the cabinet During operation these elements freeze and act as cold storage for protectin...

Страница 7: ...n that on the nameplate may cause fire or electric shock Do not store flammable or explosive substances inside these appliances e g aerosols with flammable propellant These may cause explosion or fire...

Страница 8: ...source The location must be protected against rain and dust This device cannot be used is not for use in facilities at altitudes of 2000m or higher The use of hydrogen peroxide H2O2 VHP for the disinf...

Страница 9: ...bmitting the delivery note or proof of purchase Do not operate a unit that has been damaged in transit If you are unsure contact your sales outlet and ask them The unit must be transported in an uprig...

Страница 10: ...the ice lined blood storage refrigerators Patients do not come into direct contact with the refrigerators 2 4 3 Intended use environment The Ice lined blood storage refrigerators are stationary type...

Страница 11: ...between 2 C and 6 C for no longer than five days prior to use After concentration and irradiation the storage time must be no longer than 24 hours 2 4 5 Contraindications The devices are not intended...

Страница 12: ...ctric shock may result due to corrosion The wall socket must be easily accessible When the unit is in its final position it is important to immobilise the unit using the feet CAUTION Optimal function...

Страница 13: ...e described in this manual follow the internal policy and procedures Before using the refrigerator it should be cleaned inside and outside For cleaning use only gentle cleaning agents Never use aggres...

Страница 14: ...ms with other electrical equipment causing malfunction the unit should be connected to a separate circuit Never connect it to a single socket with other electrical equipment by means of a multi socket...

Страница 15: ...ights up when there is a minimum of solar energy available Supposed that there is enough solar energy available after switching on the device starts working after a delay of 5 minutes This also applie...

Страница 16: ...nner temperature rises to high Make sure that the lid is correctly closed by using the supplied latches and that the lid gasket seals correctly against the cabinet Do not bring more than 18 new blood...

Страница 17: ...re and the displayed max and min values 4 4 3 Display In normal use the inside temperature of the appliance is displayed in the main area of the diplay C with one decimal max min main area min area ma...

Страница 18: ...error E1 4 Warning Display sensor below reading range E1 5 Warning Display sensor above reading range E2 1 Alarm Heating sensor not connected E2 2 Alarm Heating sensor short circuit E2 3 Alarm Heating...

Страница 19: ...cessary for the correct daily use of the SDD unit its presence is mandatory When it is not connected an alarm is created When it is damaged detected by a low voltage on the poles another alarm is crea...

Страница 20: ...ositioning of solar panels etc Check the actual situation of the panels and if the problem persists after corrective actions notify Refrigerator Technician Thermal cut out of electronic unit E5 5 The...

Страница 21: ...the capacity of the battery is no longer sufficient to take over the control function the alarm message E4 2 appears on the display If no battery is connected the system will generate an E4 1 alarm me...

Страница 22: ...ly gentle cleaning agents Never use aggressive or caustic cleaning agents scouring powder steel wool abrasive sponges or chemical solvents When cleaning make sure that no fluids of any kind run into t...

Страница 23: ...side air to go in and form condensation In such cases the hinges should be adjusted or the gaskets should be changed Restrict and reduce frequency of opening the MRB3000SDD Open only when absolutely n...

Страница 24: ...values Check if the ambient temperature is too high outside of the opreating range of the device which can cause the interior temperature too rise Check if there is enough air circulation arround the...

Страница 25: ...perational C Max Humididty range Altitude Refrigerant Type Refrigerant quantity g Hold over time at 32 c Hold over time at 43 c Cool down Energy consumption stable running Energy consumption cool down...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...B Medical Systems S r l op der Hei 17 L 9809 Hosingen Luxembourg...

Отзывы: