40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASED
2-26-19
REFERENCE
NUMBER
INS-2784-00
10"
(254mm)
"A/D" CAP
3" Dia.
(76mm)
2 11/16"
(68mm)
"B"/"E" CAP
(203mm)
8"
(76mm)
3" Dia.
2 11/16"
(68mm)
"C" CAP
(178mm)
7"
(76mm)
3" Dia.
Patented 360HD™
Mounting System
"B"/"E" CAP
3"
(76mm)
1"
(25mm)
"A"/"D" CAP
3"
(76mm)
5"
(127mm)
"C" CAP
2"
(51mm)
2 11/16"
(68mm)
1. Mount fixture onto suitable enclosure according
to designed lighting plan and NEC.
2. Secure ½” NPS stem to mounting option. Secure
with provided locknut if applicable.
3. Make watertight connections from remote
driver to fixture leads using waterproof wire
connectors (By Others) in splice location as per
NEC.
Fixture Installation
SARATOGA SERIES™
Remote - Solid State LED
Standard Installation
5. Rotate fixture at base and aim fixture to desired
horizontal location.
6. Tighten two (2) #8-32 stainless steel set screws
on stem to secure horizontal aiming position
4. Use 5/64” Allen wrench to slightly loosen two (2)
#8-32 stainless steel set screws on the stem for
360° aiming purpose.
7. Use 5/32” Allen wrench to loosen #10-32
stainless steel black oxide socket head cap screw
at the knuckle for vertical aiming purpose.
Tighten #10-32 stainless steel black oxide socket
head cap screw to 15 in-lbs minimum to 30 in-lbs
maximum to secure vertical aiming position.
Warning: Do not over tighten set screw.
Doing so will compromise O-ring seal and will
void warranty.