2. Place housing in hole. Align junction box in the
path of the conduit trench.
3. Insert (4) pieces of ½” EMT conduit through the
Stability Flange™. Hammer into substrate until
secure.
Leave sufficient clearance to elevate housing
to finished grade.
4. Raise housing on EMT so concrete pour collar is
flush with finished grade. Use a level to aid in
housing installation.
5. When housing is level, tighten screws on Stability
Flange™ to secure housing to EMT. Remove
excess EMT as needed.
7. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with sand
for drainage.
Housing Installation
Threaded Entry
Side Flats
1. Connect branch conduit connectors (By Others)
to the junction box using either the threaded
conduit entries on the bottom of the junction
box or through holes drilled into the sides of the
junction box.
Flush with finished grade
6. Connect the conduit to the conduit connectors.
8.
For soil installation:
Fill and tamp soil to the
appropriate height leaving room for sod, pavers,
etc. to be level with the top of the temporary
cover.
Soil installation is not drive-over rated.
9.
For concrete installation:
Fill the hole around
the fixture housing to 12” below the finished
grade with clean fill dirt and tamp carefully to
prevent settling of fixture. Pour concrete and
finish as required flush with the top surface of the
temporary cover.