RELEASE DATE
7-13-16
REFERENCE
NUMBER
INS-1341-01
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
2. Place housing in hole. Align with the path of the
conduit trench.
5. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with
sand for drainage.
Housing Installation
PROJECT:
TYPE:
1. Connect branch conduit connectors (By Others)
to the housing using either the threaded
conduit entries on the bottom of the housing
or through holes drilled into the sides of the
housing.
3. Connect the conduit to the conduit connectors.
4. Pull secondary wiring into junction box.
6.
For soil installation:
Fill and tamp soil to
the appropriate height leaving room for sod,
pavers, etc. to be level with the top of the
temporary cover.
Soil installation is not drive-over rated.
7.
For concrete installation:
Fill the hole around
the fixture housing to 12” below the finished
grade with clean fill dirt and tamp carefully to
prevent settling of fixture. Pour concrete and
finish as required flush with the top surface of
the temporary cover.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
HP
2
SERIES WITH ICEE
TM
Shallow Housing - Halogen (MR16)
Remote Transformer Installation Instructions
This product is intended for use
ONLY in areas of restricted depth.
The shallow housing does not
permit separation between the
wiring and lamp compartments.
Designer should detail the
following warning in all
specifications documents:
WARNING
MANDATORY:
Installer
MUST
use water-tight fittings and ensure
a sealed conduit/wiring system or
this fixture will leak. Failure to do
so will
VOID WARRANTY.