Fixture Installation with Stake

4.  Attach the fixture to the threads on the stake. 

Make sure the stake is secured in the ground.

 

 

2.  Remove the locknut from the fixture, leave 

the o-ring on the threads.

5.  Make watertight connections from remote 

transformer to fixture leads using waterproof 

wire connectors (by others). 

See wiring 

diagram.

6.   Use a 5/32” allen wrench to slightly loosen 

#10-32 stainless steel black oxide socket 

head cap screw at the knuckle for aiming 

purposes. Tighten to secure desired location.

LINE

12V

Fixture

COM

Remote

Transformer

COM

WIRING DIAGRAM

For use with 12VAC remote 

transformer.

Finished Grade

1.  Drive the stake into the ground with a mallet 

or a small sledge hammer (by others). Make 

sure the top is flush with the finished grade.

Finished Grade

3.  Pull the fixture wire cable throught the 

stake’s center where the hole is located. Silce 

moved the fixture wire from under the stake 

to the side to make a connection with the low 

voltage direct burial cable (by others).

 Ground wire connections is based off of 

local code requirements.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE