manualshive.com logo in svg
background image

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

PROJECT:

TYPE:

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

RELEASED

7-15-16

REFERENCE

 

NUMBER

INS-1178-02

10"

(254mm)

"A/D" CAP

3" Dia.

(76mm)

2 11/16"

(68mm)

"B"/"E" CAP

(203mm)

8"

(76mm)

3" Dia.

2 11/16"

(68mm)

"C" CAP

(178mm)

7"

(76mm)

3" Dia.

Patented 360HD™

Mounting System

"B"/"E" CAP

3"

(76mm)

1"

(25mm)

"A"/"D" CAP

3"

(76mm)

5"

(127mm)

"C" CAP

2"

(51mm)

2 11/16"

(68mm)

1.  Mount fixture onto suitable enclosure according 

to designed lighting plan.

2.  Secure ½” NPS stem to mounting option. Secure 

with provided locknut if applicable. 

3.  Make  connections  from  primary  branch  circuit 

wiring  to  fixture  leads  using  proper  wire 

connectors  (By  Others).  Connect  ground  to 

ground wire from fixture. See wiring diagram.

Fixture Installation

WIRING DIAGRAM

ALPS SERIES™

PAR38 Halogen

Standard Installation 

LINE

FIXTURE

COM

WIRING DIAGRAM

GROUND

LINE

COM

GROUND

Отзывы: