RELEASE DATE
12-19-2019
REFERENCE
NUMBER
INS-2816-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
1. Place composite housing in hole. Align
flexible conduit through 1” notch in bottom
of composite housing. Pull conduit to splice
location.
Installation
PROJECT:
TYPE:
AGI2 LED
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Soil Prep
Conduit
Trench
Excavated
for Housing
C. Prep soil according to DIG-IT Guide.
Conduit
trench
18”
Dia.
A. Determine Soil Type by referencing DIG-IT
Guide.
B. Dig hole 18” wide and deep enough for
faceplate height above grade as per lighting
plan.
2. Make watertight connections using provided
waterproof wire nuts.
See wiring diagram.
Hydrolock
Plate
LINE
COM
GROUND
DIM +
DIM -
WIRING DIAGRAM
3. For soil installation, fill and tamp soil to the
appropriate height. Fixture is above grade
specified by lighting plan.
Aiming Adjustment
1. Remove faceplate using 1/8” Allen wrench.
2. To aim OptiLock® horizontally: lift OptiLock®
from resting position, and rotate to desired
angle. Set down on pins provided in housing.
OptiLock® is gravity held in place.
3. To aim OptiLock® vertically: loosen two (2)
1/4-20 screws using 3/16” Allen wrench. Tilt
swivel arm with LED and optic in desired aiming
direction. Tighten two (2) 1/4-20 screws with
3/16” Allen wrench to secure position.
The below grade portion
of the housing to be 18”