Problem
Cause
Solution
The machine
doesn’t start .
The power supply cable is
damaged or not properly con-
nected .
No voltage in the power outlet .
Start switch is damaged .
Press the plug firmly in the power
outlet . Check the power supply
cable .
Have the power outlet checked .
Have the switch replaced .
Water doesn’t flow
at the blade but the
pump is running .
The sprayers are clogged .
The water level in the water bin
is not sufficient . The pump is not
totally submerged .
Water valve is closed .
Clean the sprayers .
Fill the water bin with clean
water until the pump is totally
submerged .
Open the valve .
Motor isn’t running
smoothly .
Water may have seeped
through inside the motor .
Capacitor is damaged .
Damaged motor bearing .
Unplug the power cable and
consult your local dealer .
Pump isn’t running . The impeller or suction filter of
the pump is damaged .
No proper connection of the
power cable .
Replace damaged parts .
Have the connection checked .
Cutting out of align-
ment .
Machine is not leveled out.
Unstable working surface .
Improper or glazed diamond
blade .
Loosen the screws for the legs .
Pick up the machine a little bit on
one end . Let the machine down
again and tighten screws . Per-
form the same procedure on the
other end . The machine should
now be leveled out .
Make sure the machine is placed
on a leveled surface .
Replace or dress the diamond
blade .
12. DECLARATION OF
CONFORMITY
We declare under our sole responsi-
bility that this product is in conform-
ity with the following standards or
standardization documents EN ISO
12100:2010, EN 55014-1:2006,
EN 55014-2/A1:2001, EN 61000-
3-2:2006, EN 61000-3-11:2000,
EN 12418+A1:2009, conforms to the
provisions of the guidelines 2006/42/
EG, 2004/108/EEC, 2006/95/EG,
2000/14/EG, 2011/65/EU .