Protocol - Modular AC-DSP
V1_version Feb-2011
15
3. To activate the Bonus, introduce a valid coin that will be accepted. If the
validator
rejects it, introduce another coin.
4. Put dipswitch SW4 OFF. If the programming was correct, the solenoid on the
acceptance gate will make a long “click”. If the programming was not correct,
the solenoid on the acceptance gate will
NOT
“click” and you will have to repeat
the process from the start.
The process to follow to
deactivate
wide tables / bonus is as follows:
1. Place the SW1, SW2, SW3 dipswitches with corresponding configuration.
2. Put dipswitch SW4 ON. The electromagnet on the acceptance gate will make a
short “click”.
3. Place dipswitch SW4 in the OFF position. The electromagnet on the acceptance
gate will make a long “click”.
4.2
Parameters that are configurable using Tools.
As already mentioned in this manual, the modular validator AC-DSP is characterized by its high
configurability by the user.
Below are all parameters that can be configured depending on the particular needs of each
client, using the Azkoyen tools available.
GENERAL PARAMETERS
PARAMETER
DESCRIPTION
Recuperation code
Assign code to the acceptance gate
Reject code
Assign code to the rejected coins
Inhibition/ Service request level
(pin 6).
**
Assign voltages 5/0 volts to the logic levels 1/0
Activate / Deactivate Wide tables
Activate / Deactivate Bonus
Output signal levels.
**
Assign voltages 5/0 volts to the logic levels 1/0
Tokens
Assign values of the tokens