Cables

Except for 24 V AC models, use a power cable rated at 600 V or 

more and 70 °C or higher.

For 24 V AC models, use a power cable rated at 60 V or more 

and 70 °C or higher.

The auxiliary switch cable should be rated at a voltage sufficient 

for the operating voltage and rated at 70 °C or higher.

For other signal lines, use cables rated at 60 V or more and 

70 °C or higher.

 

l

Relay contact input (ECM3000D and ECM3000F)

1

2

M

L

R

G

Y

T

3

4

5

6

7

Not used

*1

*2

*2

*2

L:  counterclockwise (CCW) rotation
R:  clockwise (CW) rotation
CW: Clockwise CCW: 

Counterclockwise

*1.  The supply voltage varies depending on the model. 

 MODEL SELECTION TABLE (page 2 )

*2. Terminals 4–6 of the ECM3000D are not used.

 Handling Precautions

•  The default setting for the output shaft is 0 % opening.

 

l

Potentiometer input (135 Ω) (ECM3000E)

1

2

W

24 V AC

F.G.

B

R

R

L

3

4

5

6

7

*

Not used

L: counterclockwise (CCW) rotation
R: clockwise (CW) rotation
* For details on TY9000, etc., contact the azbil Group.

 

l

4–20 mA input (ECM3000G)

1

2

*

4–20 mA DC

F. G.

+

3

4

5

6

7

Not used

*  The supply voltage varies depending on the model. 

 MODEL SELECTION TABLE (page 2 )

 Note

•  The 4–20 mA input circuit is isolated from the power circuit 

inside the device.

 Handling Precautions

•  During motor operation, in order to stop hunting (which 

causes the controller’s internal relay to turn ON and OFF 

excessively), change the parameters of the controller. For 

example, set the derivative time (D) to 0 seconds, set a 

wider dead band, etc.  

If the internal relay operates excessively, the life of the 

motor or the host controller relay will be shortened.  

If frequent operation cannot be avoided, install an auxiliary 

relay between the motor and controller.

•  The feedback potentiometer of the ECM3000F is a com-

bination resistor consisting of two different resistors con-

nected in parallel.  

Accordingly, the angle of rotation of the ECM3000F is pro-

portional not to the resistance of the feedback potentiom-

eter but to the voltage ratio between the potentiometer 

terminals (T–G voltage or Y–G voltage).  

The resistance of the feedback potentiometer cannot be 

used to measure the angle of the motor rotation.

 

l

Auxiliary switch (up to 4)

A1

A2

A3

R

COM

L

L: counterclockwise (CCW) rotation 
R: clockwise (CW) rotation

Note:  The internal connections of switches B, C, 

and D are the same as those of switch A.  
Models with forced open/close function 
have only auxiliary switches A and B. 

 

l

Forced open/close input

(a) Forced fully closed (b) Forced fully open (c) Automatic operation

CCW CW CONT S

CCW CW CONT S

CCW CW CONT S

 Handling Precautions

•  Before shipment, terminals CONT and S are connected. 

Disconnect these terminals if operation with the valve 
forced fully open (or closed) is desired. 

•  Only one of terminals CCW, CW, and CONT can be con-

nected to terminal S. Multiple terminals cannot be con-
nected to terminal S.

•  Be sure to connect non-voltage contacts to terminal S, 

CONT, CW, or CCW of an ECM3000 model with a forced 
open/close function. If 24 V AC is applied, the circuits will 
fail. 

•  If the same signal is input to multiple control motors that 

are connected in parallel, faulty operation may result.  
The same contact signal cannot synchronize multiple 
ECM3000 motors.

 

l

If the ECM3000E is used to fully open/close the valve

4

5

6

1

2

W

XO

W

B

R

Azbil Corporation's 

L91 pressure regulator

Transformer

Power supply

ECM3000E

(resistance input of nominal 135 Ω)

Switch for

full open

XO

XC

100 % when XO is open

0 % when XC is open

Switch for

full close

XC

B

R

T

1

T

2

Note:  Recommended contact rating for XO and XC  

Material: Gold plating  
Rated voltage: 15 V DC min.  
Rated current: 100 mA

Содержание ECM3000 Series

Страница 1: ...d technical skills related to this device and associated equipment Be sure to use this device correctly within the ranges specified in this user s manual Otherwise device fail ure or malfunction could...

Страница 2: ...ive load including inrush current with forced open close function 6 8 1 GB compliant models are not compliant with UL or CE standards 2 Direct reverse operation can be switched and zero point span and...

Страница 3: ...erminal is properly grounded 100 max using at least 2 mm2 wire and M4 crimp terminals with insulating sleeves During wiring open a knockout hole 22 mm dia on either side and pull out the cables from t...

Страница 4: ...ometer of the ECM3000F is a com bination resistor consisting of two different resistors con nected in parallel Accordingly the angle of rotation of the ECM3000F is pro portional not to the resistance...

Страница 5: ...ter AUXILIARY SWITCH OPTIONAL Adjustment z z Operating point An auxiliary switch can turn on if the arrow on the setting dial A B C or D is aligned with the mark The operating point can be set in a ra...

Страница 6: ...positioned within the scale 5 Turn the auxiliary switch unit counterclockwise until it clicks 6 Align the holes on the terminal block bracket with the holes on the chassis 7 Insert and tighten the 2 s...

Страница 7: ...e cable diameter 7 to 9 mm Material Case Die cast aluminum Cover Glass containing polycarbonate resin Bracket Steel Installation location Indoors Altitude 2000 m max Pollution degree 3 Mass Approx 3 k...

Страница 8: ...e like z z Auxiliary switch Item Specifications Auxiliary switches 4 or 2 Contact rating Standard model 250 V AC 100 mA to 5 A resistive load 100 mA to 3 A inductive load Low current model 250 V AC 1...

Отзывы: