Azbil AB-7352-U Скачать руководство пользователя страница 3

AB-7352-U 

 

  CAUTION 

(2/2)

 

  Use full face gaskets for flat face flanges to prevent the product damage or fluid leakage. 

 

  For installation, do not mount the valve in an improper position or overtighten the bolts on the flange. Doing so 

might damage the product. 

 

  After installation, make sure no fluid leaks from the valve-pipe connections. Incorrect installation might cause fluid 

leakage. 

 

  Install the product so that no foreign objects remains inside the pipes. Be sure to provide a strainer on the inflow 

side of the piping. Flush the piping to remove the foreign objects after installation. Foreign objects inside the piping 
might damage the product.. 

 

  Do not allow the fluid to freeze. Doing so might damage the valve body and cause fluid leakage. 

 

  Do not put load or weight on the actuator of the product. Doing so might damage the product. 

 

  Do not install the product nearby a steam coil, pressurized hot-water coil, or any high heat source. High 

temperature radiation might cause malfunction of its actuator. 

 

  Do not use the product in an atmosphere corrosive to the actuator, valve, and their components. Doing so might 

damage the product. 

 

  Do not carelessly touch this product when being used to control hot water or steam. The product temperature is hot, 

and you might get burned. 

 

  Use crimp terminals with insulation for connections to the product terminals. Failure to do so might cause short 

circuit leading to fire or device failure. 

 

  Firmly tighten the terminal screws. Insufficient tightening of the terminal screws might cause fire or overheating. 

 

  Do not touch the moving parts of the product. Doing so might cause injury. 

 

  Dispose of this product as industrial waste in accordance with your local regulations. Do not reuse all or part of the 

product. 

 

  Do not allow any shock on the product. Doing so might damage the product. 

 

  Do not disassemble the product. Doing so might cause device failure. 

 

  During engineering work, do not touch the uninstructed area other than the setting switches. Doing so, you might 

be burned. Temperature of some parts of the actuator becomes high. 

 

IMPORTANT: 
 

In case an Azbil Corporation product fails, you are required to provide your Equipment with safety design such 

as fool-proof design*

1

, and fail-safe design*

2

 (anti-flame propagation design, etc.), whereby preventing any 

occurrence of physical injuries, fires, significant damage, and so forth. Furthermore, fault avoidance*

3

, fault 

tolerance*

4

, or the like should be incorporated so that the said Equipment can satisfy the level of reliability and 

safety required for your use. 

 

*1. A design that is safe even if the user makes an error.  
*2. A design that is safe even if the device fails.  
*3. Avoidance of device failure by using highly reliable components, etc.  
*4. The use of redundancy. 

 

IMPORTANT: 

  When installing the product with a flange gasket, do not allow the gasket going inside the pipe. 

  The service life of ACTIVAL operated with small dead band can be shortened since the ACTIVAL operates 

more frequently with small dead band than with normal dead band. 

  To operate the product with small dead band, provide shielded cable for input/output signal lines and power 

line.  Unshielded cable might cause error due to noise 

 

Содержание AB-7352-U

Страница 1: ...t water control and for steam control applicable to high differential pressure large Cv value high rangeability and low leakage Durable actuator with low power consumption Equal percentage flow charac...

Страница 2: ...e product might cause injury or product damage Detach the cover only when wiring setting the product or maintenance and reattach the cover after wiring setting the product or maintenance Failure to do...

Страница 3: ...the terminal screws might cause fire or overheating Do not touch the moving parts of the product Doing so might cause injury Dispose of this product as industrial waste in accordance with your local...

Страница 4: ...specifications Item Specification Model Two way valve with flanged end connection proportional control Body pressure rating ANSI Class125 equivalent Max working pressure 230 psig End connection ANSI...

Страница 5: ...Valve and actuator as a single unit specifications Item Specification Environmental conditions Rated operating condition Limit operating condition Transport storage conditions packaged 2 Ambient tempe...

Страница 6: ...1 7 09 0 75 4 41 9 lb DN65 mm 314 124 190 90 20 140 180 19 19 kg VY5198K0081S 147 3 in 12 40 4 92 7 99 3 94 0 87 6 00 7 48 0 75 4 48 7 lb DN80 mm 315 125 203 100 22 152 4 190 19 22 1 kg Model VY5198H0...

Страница 7: ...AB 7352 U 7 Parts Identification Figure 2 Parts identification...

Страница 8: ...ication of the selector switches Figure 3 Selector switches Open close selector switch for input signal failure If no control signal is input the actuator automatically closes 0 or opens 100 the valve...

Страница 9: ...rrow indicated on the valve body Installation location CAUTION Do not install the product nearby a steam coil pressurized hot water coil or any high heat source High temperature radiation might cause...

Страница 10: ...position the valve and flush the pipes with the ACTIVAL installed at the maximum flow rate to remove all the foreign substances Factory preset position 0 For steam control drain retained water conden...

Страница 11: ...ept when connecting disconnecting wires Do not leave any refuse including metal chips after cutting a knockout hole and after connecting the wires inside the actuator Do not connect 24 V AC power to t...

Страница 12: ...terproof the wiring port For cable connection use a water proof connector Seal connector Part No 83104346 003 is recommended For conduit connection use a water proof plica tube or the like Terminals c...

Страница 13: ...transformer is required for ACTIVAL Transformer without isolation might damage the ACTIVAL and other devices connected to ACTIVAL Model SDC35 SDC36TC0 Model VY5198K VY5198H 4 to 20 mA DC input with 4...

Страница 14: ...Auxiliary switch Part No 83165274 001 Switches A and B actuating position Adjustable between 0 fully closed and 100 fully open Figure 11 Internal connection of Part No 83165274 001 OP1 OP2 OP3 N C N O...

Страница 15: ...es not operate at all Conditions of the power applied and of the input signal applied Loosened terminals Wiring condition disconnected wires Check the power supply and the controller connected to Tigh...

Страница 16: ...AB 7352 U Rev 4 0 Jun 2016 AB 7352 U 16 ACTIVAL is a trademark of Azbil Corporation in Japan or in other countries...