Troubleshooting
Not all the following problems are malfunctions.
Problem
Possible Causes
Dehumidifier is not operating.
Controls can not be set.
Unit is operating in an area where temperatur eis higher
than 32
ºC or lower than 5 ºC.
Bucket is full.
Noise suddenly rises during
operation.
Noise will rise if compressor has just started.
Power supply problém.
Unit is placed on uneven floor.
Humidity does not drop.
Area to be dehumidified i stoo large. The capacity of
your dehumidifier may not be adequate.
Doors are open.
There might be some device product vapor in the room.
Room temperature is too low.
Humidity level may be improperly set.
If unit is operating in a room where temperature is from
5 to 15
ºC, it will start to defrost automatically.
Compressor will stop for a brief period of time (fan will
operate in high fan speed).
When unit finishes defrosting, it will be back to normal
operation.
When first operated, the air
emitted has musty-odor..
Due to temperature rising of heat exchanger, the air may
have some strange smell at the beginning.
Unit has noises.
There might be some noise if unit is operating on
wooden floor.
Swooshing sound is heard.
Normal. This is the sound of the flow of refrigerant.
Problem of Water Leakage.
Problem
Possible Causes
Solution
When using drain
hose, there is water
in the bucket.
Examine the drainage
joint.
Connect the drainage joint well.
Drain hose is not correctly
installed.
Clear the obstacle from the drain
hose.
Drain hose is not correctly
installed.
Remove the drain hose and
replace it. Be sure that the hose is
correctly installed.