background image

 

 

Setting up the unit

 

The ERO L90 movinghead will reset itself after activating it. There is a possibility that shocking 
movement and flickering takes place, as the fixture has to calibrate all 0-points for every stepping 
motor (pan, tilt, gobowheel, colorwheel, prism, etc.). Give the movinghead time to calibrate all stepping 
motors. When this is finished, the movinghead will turn to its last used function, which is mostly DMX, 
while displaying the DMX address. The display shows the following codes: 

Menu 
item 

Submenu 

Feature 

Value 

Description 

ADDR 

AXXX 
A001 

Indicates the starting address while set 
to  DMX  mode  (A001  is  also  used  for 
slave devices) 

PLAY 

RUN 

MSTR/ALON 

Run  this  fixture 

as  ‘master’  or  ‘stand-

alone’ in automatic mode 

AUDI 

MSTR/ALON 

Run  this  fixture  as  ‘master’  or  ‘stand-
alone’ in music controlled mode 

AUTO 

Clos/Hold/Auto/Audi  No DMX status 

RESE 

ALL 

Reset all stepping motors and return to 
blackout mode 

SCAN 

Reset only pan/tilt motors 

COLR 

Reset only color wheel motor 

GOBO 

Reset only gobo/gobo rotation motor 

OTHR 

Reset other motors (prism etc.) 

RPAN 

ON/OFF 

Reverse pan movement 

RTLT 

ON/OFF 

Reverse tilt movement 

FINE 

ON/OFF 

Switch 

between 

8-bit 

and  16-bit 

movement 

MIC 

M-XX 
M-70 

Microphone 

sensitivity 

(for 

music 

controlled mode) 

DISP 

VALU 

D-XX 
D-00 
DXXX 

Display the value of each DMX-channel 

D ON 

ON/OFF 

Turn  the  display  off  after  2  minutes  of 
menu-inactivity 

FLIP 

ON/OFF 

Flip  the  display  180  degrees  for  easy 
display  reading  while  in  hanging 
position 

SET 

DFSE 

ON/OFF 

Reset all fixtures to default settings 

 

 

FEED 

ON/OFF 

Pan/tilt 

automatic 

error 

correction 

ON/OFF 

 

 

FANS 

AUTO/HIGH/LOW 

Fan mode selection 

 

 

SAVE 

OFF/1-99M 15M 

Stand-by mode (Power save mode) 

 

 

VER 

V1.0 

– V9.9 

Software version 

 

 

FIX 

CODE 

CXXX = Fixture code (Code = C050) 

CH01 

– CHXX 

XXXX (-128 

– 127), Motor fix 

10 

Edit 

SEPR 

AUTO 
IP01 

– IP07 

Select program to be edited 

 

 

STEP 

S-01 

– S-48 

Select step to be edited 

 

 

SCXX 

C-01 

–  C-XX  (with 

value 

0-255 

per 

channel) 

Edit  the  channels  and  values  of  each 
scene 

TIME  (XXX,  value 
001 

– 999) 

Set the time for each scene 

CEDT ON/OFF 

Edit program with controller 

 

 

REC. 

RE.XX 

Auto save function 

 

 

RUN 

ON/OFF 

Program test function 

Содержание ERO L90

Страница 1: ...1 90 Watt LED movinghead User manual...

Страница 2: ...proper bolts is also possible Make sure there are no flammable objects in the direct environment of the device Do not block the beam exit and fan Keep a minimum distance of 0 25 meter from any walls...

Страница 3: ...a longer period of time disconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with th...

Страница 4: ...verview 1 Beam output 2 Control panel with display and menu functions 3 On off switch 4 Fan 5 Power input twist lock system 6 Power link Power output twist lock system 7 DMX input 8 DMX output 9 Lifti...

Страница 5: ...nly color wheel motor GOBO Reset only gobo gobo rotation motor OTHR Reset other motors prism etc 4 RPAN ON OFF Reverse pan movement 5 RTLT ON OFF Reverse tilt movement 6 FINE ON OFF Switch between 8 b...

Страница 6: ...e internal programs on a set speed or music controlled while the other connected fixtures will mimic the first fixture thus creating synchronized light shows DMX mode Control the fixture with a standa...

Страница 7: ...ing Gobo 6 70 79 Rotating Gobo 7 80 95 Rotating Gobo Shake 1 96 111 Rotating Gobo Shake 2 112 127 Rotating Gobo Shake 3 128 143 Rotating Gobo Shake 4 144 159 Rotating Gobo Shake 5 160 175 Rotating Gob...

Страница 8: ...4 Reset functions and internal prorgrams 0 39 No function 40 79 Macro 80 84 All motors reset 85 87 Scan motors reset 88 90 Color motors reset 91 93 Gobo motors reset 94 96 No function 97 99 Other moto...

Страница 9: ...acket always mount your hooks first After mounting the hooks to your Omega type bracket carefully place the contact points of the bracket on each slot provided at the bottom of the unit Tighten the qu...

Страница 10: ...eases the chance of damage during transport Replacing the internal fuse First check whether a failing power supply may be the cause of malfunction When you suspect that the internal fuse is broken the...

Страница 11: ...al deformities should not be present If any visual or mechanical damage is detected contact your local dealer or a specialized technician Do not use a damaged or failing fixture Connectors and wiring...

Страница 12: ...infinite motorized focus with 15 degrees projection angle 0 100 dimmer with 1 18Hz strobe function LED shutter with variable speed random strobe and pulse effects DMX 512 Master Slave Sound activated...

Отзывы: