background image

Installation and connection requirements

Now that you know how the ALO Micro Scan works, it's important to know how to use it correctly and safely, 
according to the installation and connection requirements. 

Make sure the device and connection cables are out of reach of children, and that if children are present, 
they are under adult supervision at all times. Because this device can be used upright or suspended, children
could pull on the cables, causing the device to fall on top of them. To avoid injury, it is important to pay close 
attention to the position and/or installation of this device. 

Upright use

It is not recommended to use the ALO Micro Scan in an upright position because it would be rest on the 
cooling fins. This is a small surface compared to the rest of the housing, and does not offer enough stability 
for the device to function properly, especially when cables are connected to it. 

Suspended use (brackets)

When suspending the ALO Micro Scan, use the mounting bracket that has already been attached on the rear
of the device. 

If you want to mount a half coupler or a G-hook to the brackets, a hole is present in the bracket to mount 
such hardware You can find standard hooks and/or brackets for 35 or 50mm tubes (truss or light stand) at 
your local dealer. 

Hardware for mounting the ALO Micro Scan to a wall, ceiling, or beam is not included. Contact a specialist if 
you're not sure which hardware is required for your situation. A wooden beam and stone wall require different
mounting methods. 

Should you want to suspend the ALO Micro Scan, you will need to attach a safety cable to the armature. This
is not included, but is available at your local dealer. The ALO Micro Scan is already equipped with an eyelet 
for hooking a safety cable. Once it's hooked on, you can wrap the cable around the truss or light stand and 
attach it again by means of the same hook. This ensures the device is secured and prevents it from falling, 
even if one or both of the brackets should come loose. 

Ensure that the safety cable has a load capacity of 10x the weight of the armature and that the device can 
not fall farther than 30 cm. You can wrap the safety cable around the truss or light stand several times to 
ensure the fall is as short as possible. The shorter the fall, the less chance of damage or injury.

Light source

The ALO Micro Scan contains powerful LED modules that create an even more powerful effect thanks to a 
special lens that bundles the beams together. Never look directly into the lens from at close range, as the 
human eye can't adjust to the sudden intensity of the beam of light this device produces. It won't result in 
permanent injury, but it can cause temporary blind spots, which may cause disorientation and discomfort. 

Cooling

The ALO Micro Scan is cooled by fans that are installed in the housing. They are activated when the device 
turns on. Make sure the fan or ventilation slots are not blocked and regularly check that they are functioning 
normally. Be aware that should the fan suck in substances like dust, smoke and moisture, this may impair its 
operation and shorten the life of the device.

Parts and repair

This product does not include spare parts and can not be repaired by the user. All inspections and overall 
maintenance should be done by a specialist.

Cleaning and maintenance

Clean the exterior of this device monthly with a dry, or slightly damp microfibre cloth. Ensure that the device 
is unplugged before cleaning it. 

The information in this user manual is subject to change at any time without notice.

Version: 1.0

Date of creation and author's initials:18-02-2017 RV

Revision date and author's initials: -

Содержание 9000-0031-5820

Страница 1: ...an LED scanner User manual The information in this user manual is subject to change at any time without notice Version 1 0 Date of creation and author s initials 18 02 2017 RV Revision date and author...

Страница 2: ...on properly or if you have any issues while operating it please remove the plug from the power socket and contact your dealer for assistance Box contents ALO Micro Scan LED scanner power cable from IE...

Страница 3: ...ned up and any hardware or software that may be present should not be modified To achieve optimal performance inputs on this device should not be fed with a signal higher than necessary The device sho...

Страница 4: ...d become familiar with the functions of this device before using it Should the device not be used in the manner described in this user manual damages or even injuries could occur Ayra cannot be held r...

Страница 5: ...s much as possible from pollution CE The CE logo indicates that this product meets the European norms and requirements to which it must legally conform Only suitable for indoor use this product was on...

Страница 6: ...knobs 6 DMX output via 3 pin XLR 7 DMX input via 3 pin XLR 8 eyelet for optional safety cable 9 power output unprotected max 9 A 10 power input with fuse holder The information in this user manual is...

Страница 7: ...ation Address A001 A512 CHND Channel mode selection 1CH 8CH 10CH RCND Remote Control mode Specific addresses available for compatible controllers RC 1 4 adjustable SLND Slave mode Master NAST Slave 1...

Страница 8: ...automatic programs as in the SHND mode but they run at an automatic speed The user can adjust the speed between 1 and 9 where 1 is the slowest and 9 is the fastest speed SPLC This device has a colour...

Страница 9: ...evice will move in sync with the music and provide an automated light show When there is no music for the device to detect or when only high frequencies are audible the device will continue its progra...

Страница 10: ...47 SPLC3 048 055 Yellow 056 063 SPLC4 064 071 Green 072 079 SPLC5 080 087 Dark blue 088 095 SPLC6 096 103 Light blue 104 111 SPLC7 112 127 Magenta 128 255 Rainbow effect slow fast 4 Gobo wheel 000 007...

Страница 11: ...PLEASE NOTE the SPLC colours will not work if SPLC is not activated See 8CH mode CH3 6 Gobo wheel See 8CH mode CH4 7 Shutter See 8CH mode CH5 8 LED dimmer 0 0100 000 255 0 100 9 Movement speed 000 255...

Страница 12: ...This is more than enough to supply power to multiple devices of the same type via a single power line Bear in mind that the installed fuse in the ALO Micro Scan is designed to only protect the device...

Страница 13: ...et for hooking a safety cable Once it s hooked on you can wrap the cable around the truss or light stand and attach it again by means of the same hook This ensures the device is secured and prevents i...

Страница 14: ...an is equipped with a manually adjustable focus that s positioned under the reflective moving mirror Preferably the focus should be adjusted when the device is turned off or carefully while the device...

Страница 15: ...y switch on the DMX controller The device is not reacting there is no DMX signal indication Make sure the XLR cables are connected properly and are not defective Replace if necessary The device does n...

Страница 16: ...Slave mode it will wait for a master signal unless there is a DMX signal present Set the device to Master to activate the sound controlled or automated operation modes The information in this user ma...

Страница 17: ...0V power supply with IEC C13 14 inputs and outputs max 9A 400Hz constant current LED driver to be used in environmental temperature 0 40 degrees Celsius housing temperature under normal conditions 43...

Отзывы: