6- OPERATION 

The main switch (MS in Figure 5.1) is power on/off switch of the system. When it is in ON position, 
system starts to work as an emergency rescue system. If AC power is present, system bypasses AC 
power input to AC output. Otherwise, system generates AC signal from battery voltage and supply AC 
output. When MS is in OFF position, only battery charger unit works if AC power input is present. 
 
The battery fuse (BF in Figure 5.1) shuts down the emergency rescue system completely by separating 
the batteries from the device. Therefore it should always be in ON position when the device is used. 
However when the device is not used for a while, then it is recommended to switch off BF to protect 
the batteries for loosing charge. 
 
The device has three separated group of connection terminals. They are AC power input, AC output 
and battery connections. AC power input is connected to the line voltage. The batteries are charged 
and do not supply any current to the system as long as the line voltage is present. In case of any power 
breakdown, UPSLIFT immediately stops charging the batteries and starts to use them as energy source. 
Output circuit which supplies energy to the peripherals is always active. The device keeps the output 
voltage stable at 220V whatever the line condition is. The device keeps the peripherals in the shaft 
unaffected in the transition period where the line power fails. 
 
UPSLIFT will stay alive for one hour after a power breakdown. At the end of this period, it enters sleep 
mode to protect the batteries from excessive discharging. However the device can be awaken at any 
time when the RESET input is activated manually provided and the main switch is in ON position. It 
stays one more hour alive before going to sleep mode again. So the device can be used lots of time for 
a period of one hour by resetting until the batteries are getting discharged and unable to drive the 
system any more. 
 

 

Table 6.1 LED Indicators 

Name 

LED Indicator  Explanation 

5V 

ON 

Board supply is normal. 

OFF 

Board supply is off. 

MCU 

ON 

System is powered but the microcontroller is not working. 

OFF 

System is not working. 

Blinking 

System is working normally. 

ERROR 

ON 

There is an error. 

OFF 

No errors. 

BYPASS 

ON 

Line voltage is connected directly to the output circuit. UPSLIFT is not 
active. 

OFF 

Output voltage is generated by UPSLIFT.  

15V 

ON 

Internal 15V is present. 

OFF 

Internal 15V failed. 

BAT 

ON 

Batteries are connected to the device. 

OFF 

Batteries are not connected or battery fuse is off. 

 

 

 

Содержание UPSLIFT

Страница 1: ...UPSLIFT EMERGENCY POWER SUPPLY FOR LIFTS USER MANUAL Version 1 2...

Страница 2: ...batteries It can be used in all kinds of controllers 2 Warning and Remarks Read user manual before starting to install the device Do not connect or disconnect any wire from terminals of the device whe...

Страница 3: ...imum 4 Ah See chapter 4 for selection Cutdown Battery Voltage 25V Max Input Current 30A Maximum Storage Temperature 70 oC Minimum Storage Temperature 20 oC Maximum Operating Temperature 70 oC Minimum...

Страница 4: ...3 2 Mechanical Dimensions mm Model H2 W d H1 UL180 210 180 125 170 Table 3 3 Mounting Dimensions mm Model d1 d2 d3 b1 b2 b3 a1 a2 UL180 106 190 53 10 30 18 37 13 9 Figure 3 1 Mechanical Dimensions Fi...

Страница 5: ...r then the current taken from the batteries by the motor should be taken into account for selecting the charge capacity of the batteries Table 3 2 shows the required wire cross sections and battery ca...

Страница 6: ...ments LUP Input Phase Terminal Line Voltage NUP Input Neutral Terminal PE Earth Connection LP Output Phase Terminal Emergency controller power supply outputs connected to the power supply input of the...

Страница 7: ...it which supplies energy to the peripherals is always active The device keeps the output voltage stable at 220V whatever the line condition is The device keeps the peripherals in the shaft unaffected...

Страница 8: ...be a fault in electronic board Check the BF battery fuse It must be present not broken 2 There is no output voltage in normal operation Check LUP NUP terminals There should be an input voltage at 220...