1-General Description 

 
UPSLIFT is an uninterruptable power supply designed for lift applications. It has been designed 
to supply energy to the controller as well as to all peripherals such as doors, brakes, etc. in 
case of any power breakdown. It does not supply any energy to the motor. Therefore, in a 
system where UPSLIFT is used as emergency power supply then the motor should be fed either 
by batteries or by another UPS. UPSLIFT makes use of five 12V dry batteries. It can be used in 
all kinds of controllers. 

 

2- Warning and Remarks 

 

Read user manual before starting to install the device. 

 

Do not connect or disconnect any wire from terminals of the device when it has been 
energized.  

 

Place  the  device  into  the  controller  box  by  leaving  suggested  distances  around  the 
device according to figure 2.1. Otherwise the device may suffer from excessive heat. 

 

Do not store and run the device in water or in excessive cold, hot, moisty and dusty 
environments and where chemical gases are present. (see technical specifications) 

 

Do not mount the device to be exposed to direct sunlight. 

 

 

Figure 2.1:  Recommended Mounting Distance [mm] 

Содержание UPSLIFT

Страница 1: ...UPSLIFT EMERGENCY POWER SUPPLY FOR LIFTS USER MANUAL Version 1 2...

Страница 2: ...batteries It can be used in all kinds of controllers 2 Warning and Remarks Read user manual before starting to install the device Do not connect or disconnect any wire from terminals of the device whe...

Страница 3: ...imum 4 Ah See chapter 4 for selection Cutdown Battery Voltage 25V Max Input Current 30A Maximum Storage Temperature 70 oC Minimum Storage Temperature 20 oC Maximum Operating Temperature 70 oC Minimum...

Страница 4: ...3 2 Mechanical Dimensions mm Model H2 W d H1 UL180 210 180 125 170 Table 3 3 Mounting Dimensions mm Model d1 d2 d3 b1 b2 b3 a1 a2 UL180 106 190 53 10 30 18 37 13 9 Figure 3 1 Mechanical Dimensions Fi...

Страница 5: ...r then the current taken from the batteries by the motor should be taken into account for selecting the charge capacity of the batteries Table 3 2 shows the required wire cross sections and battery ca...

Страница 6: ...ments LUP Input Phase Terminal Line Voltage NUP Input Neutral Terminal PE Earth Connection LP Output Phase Terminal Emergency controller power supply outputs connected to the power supply input of the...

Страница 7: ...it which supplies energy to the peripherals is always active The device keeps the output voltage stable at 220V whatever the line condition is The device keeps the peripherals in the shaft unaffected...

Страница 8: ...be a fault in electronic board Check the BF battery fuse It must be present not broken 2 There is no output voltage in normal operation Check LUP NUP terminals There should be an input voltage at 220...

Отзывы: