2-

 

Electrical Connections

 

 

 

2.

1 Connect the CANBUS cable terminals of the LOPs to the corresponding socket on the 

control panel. (100-1000-CL1-CH1). 

2.2

 

If your system has a pit control unit with CAN interface as shown in Figure 4, connect 

all LOPs  to this unit wth CAN-BUS cables with dual white rectangular sockets. 
2.3

 

If there is no electronic pit control card with serial communication, connect the LOP 
on the lowest floor as shown in Figure 5 and complete the process. 

3- Operation and Setting Procedures 

Select the display you have used for display settings from EK04 and follow the 
instructions.  

After completing the settings, close the top cover of the LOP. 

 

 

Figure 4

 

Figure 5

 

Содержание EVOS Series

Страница 1: ...APPENDIX 3 LANDING OPERATION PANEL INSTALLATION EVOS SERIES SERIAL COMMUNICATION LOP INSTALLATION MANUAL Document Version v1 03 ...

Страница 2: ...ONS EK04 1 Display CLC CLT CLP EK04 2 Display SYC SYT SYP EK04 3 Display DMCx DMTx DMPx EVOS LOP Content EVOS Serial Communication LOP Mounting Dowels and Screws Installation and Usage Manuals Figure 1 Figure 2 Figure 3 ...

Страница 3: ...holes by placing the backplate where you want to install Drill holes for M6 5 dowels as shown by X in figure Drill a hole in the wall which the 40 28mm rectangular socket coming from the controller can pass trough B Insert 4 dowels into the drilled holes X Fix the backplate to the wall using 4 M4 30 screws to complete the mechanical installation ...

Страница 4: ...ll LOPs to this unit wth CAN BUS cables with dual white rectangular sockets 2 3 If there is no electronic pit control card with serial communication connect the LOP on the lowest floor as shown in Figure 5 and complete the process 3 Operation and Setting Procedures Select the display you have used for display settings from EK04 and follow the instructions After completing the settings close the to...

Страница 5: ...s steel cleaners to clean the panels 4 2 Do not use any detergent or acids to clean panels 4 3 Avoid to contact any liquid to the LOP 4 4 In case of an electrical failure switched off the LOP and contact with Aybey Elektronik Technical Service ...

Отзывы: