Do not connect the extractor hood to exhaust
ducts carrying combustion flumes
(boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-
electrical appliances (e.g. gas burning appliances),
a sufficient degree of aeration must be guaranteed
in the room in order to prevent the backflow of
exhaust gas. The kitchen must have an opening
communicating directly with the open air in order
to guarantee the entry of clean air.
When the cooker hood is used in conjunction with
appliances supplied with energy other than electric,
the negative pressure in the room must not exceed
0,04 mbar to prevent fumes being drawn back
into the room by the cooker hood.
In the event of damage to the power cable, it must
be replaced by the manufacturer or by the technical
service department, in order to prevent any risks.
If the instructions for installation for the gas hob
specify a greater distance specified above, this has
to be taken into account. Regulations concerning
the discharge of air have to be fulfilled.
Connect the extractor to the exhaust flue through
a pipe of minimum diameter 120mm.
The route of the flue must be as short as possible.
Never leave high naked flames under the
hood when it is in operation.
USE
The extractor hood has been designed exclusively
for domestic use to eliminate kitchen smells.
Never use the hood for purposes other
than for which it has been designed.
EN-6
Содержание AHV60WLED
Страница 1: ...MANUEL D UTILISATION FR AHV60WLED HOTTE VISIERE...
Страница 11: ...DIMENSIONS 105 Min 650mm Min 650mm unit mm 597 480 105 597 FR 11...
Страница 24: ...AHV60WLED EN U S E R M A N U A L COOKER HOOD...
Страница 33: ...DIMENSIONS 105 Min 650mm Min 650mm unit mm 597 480 105 597 EN 10...
Страница 44: ...BUT INTERNATIONAL 1 Avenue Spinoza 77184 Emerainville France Tous les papiers se trient et se recyclent...