Hardware Operation Manual
28
LCD display shows OWOOOS
Possible Cause:
“
W” means “warning” - there are many bad sectors on your HDD.
Fix: Change hard drives.
Invalid NVRAM message appears
Possible Cause:
NVRAM error or malfunction.
Fix:
Save settings and restart the controller. If the problem persists, contact your vendor.
Data loss for Windows 2000 during system shutdown
Possible Cause:
RAID controller is in a process of a built-in host and some data is still in cache buffer
during system shutdown.
Fix 1: Set Cache Off
Fix 2:
To shutdown, select Restart system and wait for 30 seconds, then power off the system.
Fix 3:
Shutdown host OS after shutting down controller.
Remote terminal problems
Unable to access Configuration Mode using the remote terminal interface.
Possible Cause 1:
The terminal communication settings do not match the settings of the RAID
SYSTEM RS-232 interface.
Fix:
The default settings for the RS-232 port are 115,200 Baud rate, 8 Data bits, 1 Stop bit, No Parity,
and XON/XOFF Flow control. Make sure the terminal is configured for these settings. If the settings
were changed in Configuration Mode, verify the settings of the RAID SYSTEM in the RS-232 Params,
Terminal option and change the terminal settings accordingly.
Possible Cause 2: Incompatible RS232 cable.
Fix:
Cross pins on the RS-232 cable as shown below (or use a null modem cable). The only pins used
are 2 3 & 5.
1 2 3 4 5 6 7 8 9
X I
1 2 3 4 5 6 7 8 9