0 4
A S S E M B L Y (see page 33)
EN
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and⁄or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ It is not permitted to install a shutoff device (f.e. a
single-lever mixer) upstream of the built-in valve for
3 consumers!
⁄ If the thermostat or mixer is set to maximum water
temperature, there is a risk of scalding at hydraulical
opening of the check valve. For this reason, Hansgrohe
recommends that you set up the "Safety Function".
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C ⁄ 4 min
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page 39)
F L O W D I A G R A M (see page 40)
S P A R E P A R T S (see page 42)
S P E C I A L A C C E S S O R I E S
(see page 38 + 43)
order as an extra
C L E A N I N G (see page 44)
O P E R A T I O N (see page 41)
T E S T C E R T I F I C A T E (see page 43)
+
F A U L T
C A U S E
R E M E D Y
⁄ Valve stiff
⁄ Select stop valve DN9 damaged
⁄ Exchange Select stop valve DN9
⁄ Shower or spout dripping
⁄ Select stop valve DN9 damaged
⁄ Exchange Select stop valve DN9
⁄ Pushbutton cannot be actuated or is
without function
⁄ Safety guard of isolating valve has not
been removed
⁄ Remove safety guard from isolating
valve
⁄ Pushbutton is jammed or stiff
⁄ Seal needs greasing
⁄ Grease the seal
⁄ Pushbutton does not snap in
⁄ Select Adapter incorrectly trimmed
⁄ Trim and mount Select Adapter accord-
ing to Fig. 7 (see page 34 + 37)
⁄ First, fully press the pushbutton down
into the rosette; then, mount the rosette
Содержание ShowerSelect Round 36727 Series
Страница 33: ...3 3 1 2 mm SW 4 mm 5 Nm A r m a t u r e n f e t t G r e a s e 2 1 SW 3 mm SW 5 mm 2 1 01700180 1 2 3 4 5...
Страница 34: ...3 4 1 2 SW 3 mm SW 10 mm 2 Nm 1 2 0 mm 0 mm Silicone 6 7 8 9 10 11...
Страница 35: ...3 5 X 16 1 2 mm X 2 1 0 1 Nm Silicone 12 13 14 15 16 17...
Страница 36: ...3 6 1 2 1 2 18 19 20 21 22 23...
Страница 37: ...3 7 0 mm A 0 mm max 5 a A 24 25 B C...
Страница 38: ...3 8 SW 4 mm 7 mm 1 2 92696000 40 C 2 mm 0 SW 4 mm 5 Nm a c b...
Страница 45: ...4 5...
Страница 46: ...4 6...
Страница 47: ...4 7...