21
MICROSPEED
REV 04/05
Below is information about appropriate wiring;thereby,
improving noise reduction and safety.
-Always use shielded cables to connect the ref signals
and the tacho signal.
-Signal cables and power cables must be segregated
and wired through different trunking.
-Reference the section of the cable, the factory
suggests:
1.5 mm/square up to size 6/12 for power cables.
2.5 mm/square up to size 10/20 for power cables.
4.3 Connections
Power connection
D) The oM and -M may be connected directly to
the motor terminals.
When a motor has an inductance value less than 0,7 - 0,8
mH, a choke is required,connect in series,so the form
factor is improved.
This avoids overheating the servomotor.
Содержание Microspeed 60
Страница 15: ...15 MICROSPEED REV 04 05 WARNING...
Страница 44: ...MICROSPEED 44 REV 04 05 8 5 Block diagram...