AXIS Q60-S Series
will show as active (shown under
System Options > Port & Devices > Port
Status
) if the alarm device is activated.
•
Digital input –
An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass
break detectors, etc. When a signal is received the state changes and the input
becomes active (shown under
System Options > Port & Devices > Port Status
).
I/O connector (internal) -
2–pin I/O terminal block.
Specifications
Operating Conditions
The Axis product is intended for outdoor use.
Product
Classification
Temperature
Humidity
AXIS Q6042-S
AXIS Q6044-S
AXIS Q6045-S
IEC 60721-4-3
Class 3K3
IEC/EN 60529 IP66
ISO 20653 IP6K9K
-30 °C to 50 °C
(-22 °F to 122 °F)
10–100% RH (condensing)
Power Consumption
NOTICE
NOTICE
NOTICE
Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a
rated output power limited to
≤
100 W or a rated output current limited to
≤
5 A.
Product
Power
AXIS Q6042-S
AXIS Q6044-S
AXIS Q6045-S
12 V DC, max 60 W
Connectors
SD Card Slot
Supports SD cards with up to 64 GB of storage. For best recording performance, use an SDHC
or SDXC card with speed class 10.