AXIS Q3518-LVE Network Camera
Specifications
Function
Pin
Notes
Specifications
DC ground
1
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 50 mA
Digital input or Supervised input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate. To use supervised input,
install end-of-line resistors. See connection diagram for information
about how to connect the resistors.
0 to max 30 V DC
Configurable
(Input or Output)
3–4
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with the load,
to protect against voltage transients.
0 to max 30 V DC, open drain,
100 mA
Example
1
DC ground
2
DC output 12 V, max 50 mA
3
I/O configured as supervised input
4
I/O configured as output
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to
≤
100 W or a rated output current limited to
≤
5 A.
20