AXIS M1143-L/M1144-L
Page 13
EN
GL
IS
H
Adjust image and focus
To focus AXIS M1143-L/M1144-L:
1. In the
Focus Adjustment
page in the camera’s GUI, (
Setup
>
Basic
Setup
>
Focus
), set the DC-Iris to
Disabled
and click
Save
.
2. Open the lid on the camera; adjust the zoom with the zoom puller in
the range 1-4 (1 > full wide; 4 > full tele).
3. Adjust the focus with the focus puller as required.
Note:
The lever tool can be used to adjust and tighten the zoom and
focus pullers.
4. From the
Focus Adjustment
page in the camera’s GUI, set the DC-
Iris to
Enabled
and click
Save
.
5. Adjust the
Angle of Illumination
slider in the camera’s GUI. See
note below.
Notes:
• The DC-Iris should always be disabled while focusing the camera. This opens the
iris to its maximum, which gives the smallest depth of field and thus the best
conditions for correct focusing. When the focus is set with this method it will
then be maintained in all light conditions
• The default zoom is set at 1. If the zoom is adjusted to a different value, move
the
Angle of Illumination
slider in the
IR Light
window (
Camera Settings
>
IR
Light Settings
>
Edit
) in the camera’s GUI to the same value, for optimal IR
illumination.
Focus puller
Zoom puller