AXIS M1103
Setting Up the Product
Setting Up the Product
The Axis product can be con
fi
gured by users with administrator or operator rights. To open the product’s Setup pages, click
Setup
in
the top right-hand corner of the Live View page.
•
Administrators
have unrestricted access to all settings.
•
Operators
have access to all settings except System Options
See also the online help
.
Basic Setup
Basic Setup provides shortcuts to the settings that should be made before using the Axis product:
1. Users. See
page 31
.
2. TCP/IP. See
page 33
.
3. Date & Time. See
page 33
.
4. Video Stream. See
page 13
.
The Basic Setup menu can be disabled from
System Options > Security > Users
.
Focus Adjustment
To focus your Axis product:
1. Open the Live View page in a web browser.
2. Unscrew the focus puller on the lens by turning it counterclockwise. Adjust focus as required. Re-tighten the focus puller.
Back Focus Adjustment
If the lens is changed to a non-standard lens or when the focus achieved is not satisfactory, adjust the back focus as follows:
1. Loosen the screw that holds the CS-ring. See
Hardware Overview, on page 4
2.
Direct the camera towards an object at least 7 meters away and check that it is possible to focus the camera.
3.
Direct the camera towards a close object, about 30 cm away and check that it is possible to focus the camera.
4. If it is not possible to focus the camera in step 2 or 3, adjust the CS-ring and go back to step 2.
5. Gently tighten the screw to secure the CS-ring’s position.
6. Adjust the focus position for the desired view.
12