USER MANUAL  

 

 

BLM Series 

 

 

 

 

 

 

 

 

 

 

File: 2011-10-04-BLM-136 BL010 GB

Содержание BLM Series

Страница 1: ...USER MANUAL BLM Series File 2011 10 04 BLM 136 BL010 GB ...

Страница 2: ...ng PCS 11 12 Summation of measurements series Σ 15 13 Data library LIB key 16 14 Connecting a computer or a printer 18 15 Basic function description 20 15 1 Normal weighing 20 15 2 Weighing with tare 20 16 Special function description 21 16 1 Autozeroing Autot 22 16 2 Calibration with external weight CALIb 23 16 3 Serial port parameters setting rS232 24 16 4 Print out configuration function PrInt ...

Страница 3: ...le weight or keyboard inscribed Scale avails a learn algorithm during calculation and this algorithm is correcting inaccuracy conversion Scale owns summing register This register allows to addition or subtraction of next result and observation current state of this register Scales grant claims of regulations abort safeties in European Union sign inform about that on brand table CE This type of sca...

Страница 4: ...n appropriate type supplied with the scale Pay attention that supply voltage is compatible with specified technical data Do not use the scale when its cover is opened Do not use the scale in explosive conditions Do not use the scale in high humidity If the scale seems not to operate properly unplug it from the mains and do not use until checked by authorised service According to legal regulations ...

Страница 5: ...echnical data Scale type BLM1 5 BLM3 BLM6 BLM15 BLM30 Maximum loading Max 1 5kg 3kg 6kg 15kg 30kg Reading unit d 0 1g 0 1g 0 2g 1g 1g Minimal sample weight 0 1g 0 1g 0 2g 1g 1g Pan dimension 250x180mm Working temperature 10 C 40 C Weighting time 3s Scale base dimension 255x310x107mm Scale weight 2 6kg Power supply 230V 50Hz 6VA 12V 1 2A ...

Страница 6: ..._________________________________________________ 5 General view of balance 1 pan welt pan 2 carrying pan under welt 3 LED display 4 keyboard 5 level 6 rotary legs Connections views Zasilanie Zasilacz 230V RxD odbiór TxD nadawanie masa RS232C 1 2 3 4 5 6 7 8 9 6 5 1 2 4 3 Feeder Supply ...

Страница 7: ...nu UNITS change of mass units on main display DATA change data on displays DATA HR temporary increased indication resolution B G gross weight indication switch LIB get to record base PCS start counting procedure with added sample long hold key turn on turn off function MIN OK MAX selection PCS start counting procedure with subtractive sample long hold key turn on turn off function MIN OK MAX selec...

Страница 8: ... unit displayed indicators lb oz ozt ct units of masses current indications DATA display indicators indicator B G gross mass key B G indicator T actual tare indicator PT stored tare indicator APW sample mass indicator Σ contents of summing register COUNT display indicators indicator not working indicator MIN indication under minimum threshold indicator OK indication between minimum and maximum thr...

Страница 9: ...electromagnetically or magnetically fields 8 Preparation to work 1 Take the scale pan and feeder out of the package It is recommended to keep the original scale package in order to transport the balance safely in future 2 Place the scale on a stable ground not affected by mechanical vibrations and airflows 3 Put a carrying pan 2 in wholes 4 Put the fish plate pan 1 5 Level the scale with the rotat...

Страница 10: ...ight control easier and to avoid range overdrawing the scale is equipped with a load indicator graduated in percentages 4 Weighing result should be read when the indicator lights which signalizes stabilization of a result 5 When the scale is not used but it is necessary to be ready to work immediately it can be switched off by pressing I key The scale reading system is then switched off to standby...

Страница 11: ... pieces e g turnbuckles or buttons Measurement with single pieces putting on pan A measurement is performed in two phases first phase single piece weight calculation on the basis of defined pieces amount default is 10 pieces second phase pieces counting 1 Put on pan quantified details sample 2 Turn a counting by press PCS key 3 If the quantified sample consists 10 pieces press ENTER solid line on ...

Страница 12: ...s 10 pieces second phase recalculating a weighting portion 1 Put on pan a box with details 2 Turn a pieces counting by press PCS key and confirm by ENTER key 3 Remove one or more details from the portion 4 If one detail is removed press ENTER key If amount of removed is other write correct value by using numeric keys and ENTER 5 Number of details has been showed on right display with PCS indicator...

Страница 13: ... sample mass by using a numeric keys and ENTER 3 Number of details has been showed on right display with PCS indicator A sample mass has been showed in centered display with APW 4 Result of calculation is read from right display Note 1 It is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units 2 Err PCS communicat...

Страница 14: ...____________________________________________________________ MIN OK MAX selection turn on turn off counting detail Hold a PCS PCS key causes display following options OFF disable a counting details on enable a counting details thr setting a threshold selection MIN OK MAX 3sek ...

Страница 15: ...ring a pass a threshold scale turn on buzzer Note On the first start scale value of thresholds are set to maximum During a setting a upper threshold remember that his value can t be lower that value of minimum threshold 12 Summation of measurements series Σ Σ Σ Σ Scale is equip In summation register That registers enable addition a next result of measurements 1 Put element on the pan and press Σ Σ...

Страница 16: ...f finding the right record recalling single piece mass and other data Record library edition Longer pressing of LIB key enters edition menu On left display a Edit sign shows up and on the middle one a record identification number from 000 to 999 Next using Σ Σ Σ Σ and Σ Σ Σ Σ keys choose record number and press Enter to edit it Chosen record id will show up on the left display On the middle one fo...

Страница 17: ...firm it with ENTER key Entering record library Shortly press LIB key to enter record library in order to readout inscribed earlier record User can differ saved records green diode lights on middle screen from empty ones We choose record using Σ Σ Σ Σ and Σ Σ Σ Σ keys and confirm our choice by pressing ENTER It is also possible to inscribe directly the record number In order to do that press and th...

Страница 18: ...cale The Axis company offers programs to cooperating with scales These programs are available on site www axis pl Test RS232C program to tests serial connections full version ProCell program enabling cooperation with Microsoft Excel or different Windows applications demo version Information for programmers transmission protocol describe Signal description Computer Scale initialising signal S I CR ...

Страница 19: ...___________________________________ Connecting cable WK 1 connect scale with computer interface 9 pin Connecting cable WD 1 connect scale with printer KAFKA Settings og internal switch printer AXIS SW 1 SW 2 SW 3 SW 4 SW 5 SW 6 SW 7 SW 8 on off on off off on off off SCALE COMPUTER SCALE KAFKA PRINTER ...

Страница 20: ...on description 15 1 Normal weighing Press the T key when indication is different from zero at empty scale Weighing result should be read when the indicator lights 15 2 Weighing with tare The scale is equipped with tare equal to its range Joint value tare and netto mass can not surpass the range of weight Max 0 00 g 43 04 g 23 13 g 0 00 g 63 24 g T T ...

Страница 21: ... return to default settings dEFAU Other special functions can be enabled as an option on customer request all functions are described in additional brochure when ordered Press MENU key to enter the function menu Functions are displayed successively with consecutive numbers F1 Autot F2 rS232 etc To customise the function menu with most frequently used functions use Menu Customisation function ACtIV...

Страница 22: ...automatically ensures stable zero indication if the pan is empty or if zero indication was acquired by pressing T key To activate the function press MENU key then with ENTER key choose Autot and Aut on To leave the function press MENU key then with ENTER key choose Autot and AUt OFF Note Autozeroing function is activated automatically for 10 min after switching on 0 01g Autot Autot Autot 0FF on 0 ...

Страница 23: ... use calibration weight as stated in Technical Data table or of better accuracy Operations sequence Cause a user function by press MENU key Press ENTER key during the CALIb is displayed They will be displayed following options CAL OFF out without calibration CAL on calibration with external weight out leave option Press ENTER key during the CAL on is displayed Wait until zeroing is finished When L...

Страница 24: ... 115200 transmission speed bitS 7 8 the number bits in a byte PArIt 0 1 parity control Odd 0 1 type of parity Send continous transmission without using key To set desired transmission parameters activate rS 232 function choose appropriate parameter and press ENTER key to accept needed parameter value The example at the left presents how to set transmission speed value to 9600bps To leave the funct...

Страница 25: ...tor code max 6 digits dAtE date tIME time Pr no number of print out choose his function is clearing a counter PA no product number 13 digits Count counting result totAL ammount of results APW netto mass tArE actuall tare value GrOSS gross mass If the function OPEr is checked operator code can be inscribe directlty by press key The example at the left presents how to set header and operator code se...

Страница 26: ...nd setting a PIN code to protect by non authorized changes This function is installed on the special order Press ENTER key during the dAtE is displayed They will be displayed following options OFF turn off date on the print out on turn on date on the print out SEt setting time and date PIn access code 4 digits out leave the function 00 00 12 00 28 03 2009 0 00g 0 00g dAtE dAtE dAtE dAtE dAtE dAtE ...

Страница 27: ...ial functions that will be displayed after pressing MENU key Easy access to the most useful functions will shorten operation time and make work more comfortable User can return to factory setting using special function dEFAULt Operation sequence shown on the picture presents how to add RS232C parameters setting function to the Function Menu To remove a function from the Function Menu choose rS oFF...

Страница 28: ...services is show on site www axis pl 6 Damages scales should be sent to repair only in original package Scale should be protected against pressure Error communicates Communicate Possible cause Remedy C 1 6 over 1 min self test failed if displayed more than 1 minute contact an authorised service balance doesn t work protection rod remove protection rod and cap L pan missing put the pan on mechanica...

Страница 29: ...t of radio disturbance characteristics of information technology equipment and IEC 61000 4 3 Electromagnetic compatibility EMC Part 4 3 Testing and measurement techniques Radiated radio frequency electromagnetic field immunity test harmonised with the Council Directive 89 336 EEC Additional information Conformity evaluation for the Council Directive 73 23 EEC and 89 336 EEC were carried out by Lab...

Страница 30: ...30 OPERATION MANUAL __________________________________________________________________________________________________________________ Notes ...