Section 5: Access Control and Set-up
AXIS 850/950 User’s Manual
53
InternetAddress
ServerName
NetMask
Turning off SCSI
termination
The config.ini file has to be edited to set the SCSI parameter
SCSITermination to off.
1. In Windows, double-click the config.ini file to edit it using
the notepad editor. In UNIX, use your favourite editor.
2. Locate the line SCSITermination and change the parameter
value to off. See the example below:
Example:
3. Save the file.
4. To activate the new settings, power the Axis CD-ROM server
off and then on again. The indicators will flash during power-on
and self-test. When the STATUS indicator stops flashing and
remains unlit, the new setting is ready for use.
Changing the SMB
server name
The config.ini file has to be edited to set the SMB parameter
ServerName to the desired name.
1. In Windows, double-click the config.ini file to edit it using
the notepad editor. In UNIX, use your favourite editor.
2. Locate the line ServerName and change the parameter value.
See the example below:
Example:
3. Save the file.
…
[SCSI]
SCSITermination = off ; on/off
…
…
[SMB]
ServerName = CDSERV
…