![Axis Industries QALCOSONIC HEAT 2 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/axis-industries/qalcosonic-heat-2/qalcosonic-heat-2_technical-description-installation-and-user-instructions_3039900009.webp)
PESHEAT2V01
2016-01-08
9
- Resolution of indication of temperatures and
temperature difference
0,1
o
C
- Maximum permissible RMS value of sensor current
5,5 mkA
- Recorded errors and their duration
Θ >181
o
C (or open circuit),
Θ < -41
o
C (or short-circuit).
NOTES:
* - additional 3rd channel selects the user during on-site installation
** - selected by the customer when ordering the device
*** - depending on the value of the lower measurement limit of the temperature
difference of the connected pair of temperature sensors
2.3. Flow measurement
2.3.1. Ultrasonic flow measurement channels (sensors) 1 and 2
- Ultrasonic flow measurement sensors
(depending on the measurement circuits)
2 or 1
Heat meater flow sensor data are presented in Table 2.1
Table 2.1
Flow-rate, m³/h
Threshold
value, m
3
/h
Overall
length,
L, mm
Pressure
loss
p,
at q
p
, kPa,
not more
than
Connections end
(Thread – G, Flange –
DN)
Permanent
p
q
Maximum
s
q
Minimum
i
q
*
0,6
1,2
0,006(0,024)
0,003
110
7
G3/4“
0,6
1,2
0,006(0,024)
0,003
190
0,9
G1“, DN20
1,0
2,0
0,01 (0,04)
0,005
110
11,3
G3/4“
1,0
2,0
0,01 (0,04)
0,005
190
2,5
G1“, DN20
1,5
3,0
0,006 (0,06)
0,003
110; 165
17,1
G3/4“
1,5
3,0
0,006 (0,06)
0,003
190
5,8
G1“, DN20
1,5
3,0
0,015 (0,06)
0,003
110; 165
17,1
G3/4“
1,5
3,0
0,015 (0,06)
0,003
190
5,8
G1“, DN20
1,5
3,0
0,015 (0,06)
0,005
130
7,2
G1“
2,5
5,0
0,01 (0,1)
0,005
130
19,8
G1“
2,5
5,0
0,01 (0,1)
0,005
190
9,4
G1“, DN20
2,5
5,0
0,025 (0,1)
0,005
130
19,8
G1“
2,5
5,0
0,025 (0,1)
0,005
190
9,4
G1“, DN20
3,5
7,0
0,035 (0,14)
0,017
260
4
G1 1/4“ DN25, DN32
6,0
12,0
0,024 (0,24)
0,012
260
10
G1 1/4“ DN25, DN32
6,0
12,0
0,06 (0,24)
0,012
260
10
G1 1/4“ DN25, DN32
10,0
20,0
0,04 (0,4)
0,02
300
18
G2“, DN40
10,0
20,0
0,10 (0,4)
0,02
300
18
G2“, DN40
15,0
30,0
0,06 (0,6)
0,03
270
12
DN50
15,0
30,0
0,15 (0,6)
0,03
270
12
DN50
25
50
0,1 (1)
0,12
300
20
DN65
25
50
0,25 (1)
0,12
300
20
DN65
40
80
0,16 (1,6)
0,2
350
18
DN80
40
80
0,4 (1,6)
0,2
350
18
DN80
60
120
0,24 (2,4)
0,3
350
18
DN100
60
120
0,6 (2,4)
0,3
350
18
DN100
Remark:
1.*Values of the minimum flow rates for measurement schemes U1L and U2L (accounting of
heating-cooling energy ) are presented in brackets.