UST100-504-FL Series u
ser’s Manual
BIOS Setup Utility
45
Voltage Setting
Voltage setting is designed to protect the lead-acid batteries and keep the system
from running out of power when the lead-acid battery is low, so as not to drain the
battery. (It is strongly recommended that users should avoid changing the defaults.)
(1) Low Voltage: Notifies the system to shut down when voltage drops to the specified value.
(2) Very Low Voltage: Force turns off system power when voltage drops to the specified value.
DC Mode
Function
Configuration range
Default Value
Unit
12V
Start Voltage
Low V 1V
10.5
V
Low Voltage
9~12
9.5
Very Low Voltage
8.5~11.5
8.5
24V
Start Voltage
Low V 2V
19.5
Low Voltage
17.5~24
17.5
Very Low Voltage
17~23.5
17