background image

GOT712S-837-24-110V User’s Manual 

10 

 

Hardware and Installation

 

 

2.5 

DIO 

2.5.1  Digital I/O Specification 

 
This system supports one DIO (6 input and 2 output) with isolated 1.5KV. The pin assignments 
are listed in table below.   
 

Digital Input: 

Input channels: 6, sink/source type 
Input voltage: 0 to 30VDC at 25Hz 
Input level for dry contacts: 
Logic level 0: close to ground 
Logic level 1: open 
Input level for wet contacts: 
Logic level 1: +/-3VDC max. 
Logic level 0: +/- 10VDC min. to +/-30VDC max. (source to digital input) 

 
Digital output: 

output channels: 2, sink type 
output current: 200mA max. per channel 
on-state voltage:12~ 24VDC nominal 
max. voltage on COM+: 30VDC 
 
 

 

 
 
 
 
 
 
 
 
 

 

Pin 

Definition 

Common PWR+ 

DI4 

DI5 

DO0 

DO1 

Common PWR- 

EXT_POWER 

DI0 

DI1 

10 

DI2 

11 

DI3 

12 

Isolation GND 

Содержание GO712S-837-R-E3845-24-110VDC

Страница 1: ...GO712S 837 R E3845 24 110VDC Railway 12 1 XGA TFT LCD PANEL PC User s Manual...

Страница 2: ...manual Axiomtek reserves the right to change or revise this document and or product at any time without notice No part of this document may be reproduced stored in a retrieval system or transmitted in...

Страница 3: ...ned technician is allowed to do so Integrated circuits on computer boards are sensitive to static electricity To avoid damaging chips from electrostatic discharge observe the following precautions Bef...

Страница 4: ...2 4 Ethernet 9 2 5 DIO 10 2 5 1 Digital I O Specification 10 2 5 2 Digital I O Software Programming 11 2 5 3 Digital Input Wiring 12 2 5 4 Digital Output Wiring 13 2 6 Audio 13 2 7 CANBUS connector 14...

Страница 5: ...v 3 6 Chipset Menu 27 3 7 Security Menu 30 3 8 Boot Menu 31 3 9 Exit Menu 32...

Страница 6: ...vi This page is intentionally left blank...

Страница 7: ...712S 837 is equipped with 12 1 TFT ruggedized touch panel computer and all lockable connectors are perfect choice for Human Machine Interface HMI in railway environments The 12 1 railway touch panel P...

Страница 8: ...x RS 232 422 485 with isolated 1 5KV M12 A coded 2 x Gigabit LAN with isolated 1 5KV M12 X coded 2 x USB 2 0 M12 A coded 1 x DIO 6 input 2 output with isolated 1 5KV Phoenix type 1 x CAN bus with iso...

Страница 9: ...ass IP65 NEMA4 aluminum front bezel Net Weight 3 Kgs 6 61 lb Dimension Main Body Size 330 x 61 5 x 245 mm Operation Temperature 40 to 70 Relative Humidity 10 to 95 40 Non Condensing Power Input 24V to...

Страница 10: ...GOT712S 837 24 110V User s Manual 4 Introduction 1 3 Dimensions and Outlines The following diagrams show the dimensions and outlines of GOT712S 837...

Страница 11: ...DC for power input with isolated 1 5KV 2 CAN Bus with isolated 1 5KV 3 Audio Line out Line in speaker out 4 DIO 6 input 2 output with isolated 1 5KV 5 USB 2 0 x 2 M12 A coded 6 COM 2 RS 232 422 485 wi...

Страница 12: ...5 Packing List When you receive the GOT712S 837 the bundled package should contain the following items GOT712S 837 unit x 1 Phoenix Connector x 1 If you can not find the package or any items are missi...

Страница 13: ...ich I O ports and flexible expansions for you to meet different demand The chapter will show you how to install the hardware It includes Open back cover Serial Ports USB Ports Ethernet DIO Audio CANBu...

Страница 14: ...2 2 Serial Ports Interface This system supports RS 232 422 485 isolated 1 5KV on COM1 COM2 ports The pin assignments are listed in table below If you need to adjust these COM ports to work as RS 232...

Страница 15: ...ction can be established by plugging one end of the Ethernet cable into this RJ 45 connector and the other end to a 1000 100 10 Base T hub with isolated 1 5KV Pin Definition 1 USB1_PWR 2 USB_DN1_C 3 U...

Страница 16: ...ltage 0 to 30VDC at 25Hz Input level for dry contacts Logic level 0 close to ground Logic level 1 open Input level for wet contacts Logic level 1 3VDC max Logic level 0 10VDC min to 30VDC max source t...

Страница 17: ...ardware and Installation 11 2 5 2 Digital I O Software Programming I2C to GPIO PCA9554PW GPIO Group0 5 0 is Output Group0 7 6 is Input I2C address 0b0100100x Registers Register 0 Input Group0 register...

Страница 18: ...24 110V User s Manual 12 Hardware and Installation 2 5 3 Digital Input Wiring DRY contact Logic level 0 close to ground Logic level 1 open WET contact Logic level 1 3VDC max Logic level 0 10VDC min t...

Страница 19: ...m supports one Audio Line out Line in speaker out with isolated 1 5KV The pin assignments are listed in table below Pin Definition 1 SPEK_OUTA 2 SPEK_OUTA 3 AUDIO_GND 4 AUDIO_OUT_L 5 AUDIO_OUT_R 6 NA...

Страница 20: ...elow 2 8 DC Power connector The system supports one DC for power input with isolated 1 5KV The pin assignments are listed in table below Note 1 If the testing environment is not able to provide ACC pl...

Страница 21: ...ards You can choose either slot 1 or slot 2 to install the wireless LAN card and refer to the following Step 1 Open the back cover and find out the mini card slot on main board Step 2 Insert the wirel...

Страница 22: ...rovides one Mini card slot for user to install mSATA Please choose the slot 2 when installing the mSATA card and refer to the following instructions and illustration Step 1 Open the back cover and fin...

Страница 23: ...D indication of the device 2 11 Auto dimming Because the human eye perceiving brightness is nonlinear PWM duty must be set percentage at each stage of opening and closing LCD Backlight Level 10 100 Le...

Страница 24: ...GOT712S 837 24 110V User s Manual 18 Hardware and Installation This page is intentionally left blank...

Страница 25: ...tup menu displays You can access the other setup screens from the main BIOS setup menu such as the Advanced and Chipset menus NOTE If your computer cannot boot after making and saving system changes w...

Страница 26: ...F7 Enter ESC Arrow keys and so on NOTE Some of the navigation keys differ from one screen to another Please check the following table for the function description of each navigation key Hot Keys Desc...

Страница 27: ...can be set up as described below The Main BIOS setup screen is shown below BIOS Information Display the auto detected BIOS information System Date Time Use this option to change the system time and da...

Страница 28: ...can select any of the items in the left frame of the screen to go to the sub menus NCT6106D Super IO Configuration NCT6106D H W Monitor CPU Configuration IDE Configuration Miscellaneous Configuration...

Страница 29: ...lue of the selected option Serial Port 1 2 configuration 1 Serial port This option used to enable or disable the serial port 2 Device Setting This item specifies the base I O port address and Interrup...

Страница 30: ...s Manual 24 Drivers Installation NCT6106D H W Monitor This screen shows the Hardware Health Configuration CPU Configuration This screen shows the CPU Configuration and intel virtualization technology...

Страница 31: ...lect options for the SATA Configuration and change the value of the selected option SATA Mode Use this item to choose the SATA operation mode Here are the options for your selection IDE Mode AHCI Mode...

Страница 32: ...GOT712S 837 24 110V User s Manual 26 Drivers Installation CSM Configuration Enable is Legacy mode Disable is UEFI mode USB Configuration Display USB Device Configuration...

Страница 33: ...Menu In this section it will display the available devices on your system for you to configure the boot settings and the boot priority North Bridge This screen shows the North Bridge memory informati...

Страница 34: ...GOT712S 837 24 110V User s Manual 28 Drivers Installation South Bridge...

Страница 35: ...GOT712S 837 24 110V User s Manual AMI BIOS Setup Utility 29 USB Configuration Only support USB2 0 EHCI...

Страница 36: ...GOT712S 837 24 110V User s Manual 30 Drivers Installation 3 7 Security Menu In this section you may set change or clear the supervisor user password for the system...

Страница 37: ...e Timeout for wait press key to enter Setup Menu Bootup NumLock State Use this item to select the power on state for the NumLock The default setting is on Quiet Boot Use this item to enable or disable...

Страница 38: ...GOT712S 837 24 110V User s Manual 32 Drivers Installation 3 9 Exit Menu NOTE Load default before updating g TXE firmware and restart...

Отзывы: