Histrorical memory

Press

(6) to view histrorical memory, the last 20 measured value will be displayed in reversed order.

Press

(8) to quit historical value viewing.

7. Trouble shooting

All errors or failures will be shown as codes. The following table explains the meaning of codes and
solutions.
Code // Cause // Corrective Measure
204 // Calculation error // Refer to user manual, repeat the procedures.
208 // Excessive current // Please contact your distributer
220 // Battery low // Replace new batteries.
252 // Temperature too high // Let device cool down to operating temperature at 0°C - 40°C.
253 // Temperature too low // Warm up the device to operating temperature.
255 // Received signal too weak or measurement time too long // Use target plate or change a good reflective
surface.
256 // Received signal too strong // Target too reflective, use target plate or do not aim at strong light
objective.
261 // Outside of the range of measurement // Select the measurement distance within the range of mea-
surement.
500 // Hardware error // Switch on/off the device several times. If the symbol still appears, please contact
your dealer for assistance.

8. Specification

Specification // AX-DL100
The maximum measuring range* // 100 m
Measuring accuracy** // ±2 mm
Measuring units // m / ft / in / ft+in
Laser class // Class 2
Laser type // 630-670nm, < 1mW
Single distance measurement //
Min. / max. value //
Area, Volume Measurement //
Indirect Pythagorean theorem //
Continuous measurement //
Addition and subtraction //

Содержание AX-DL100

Страница 1: ...d by globally recognized team the AX DL100 laser distance meter is compact and handy The innovative design with clip accessory enables user to bring the meter anytime as well as it also protect the ba...

Страница 2: ...3 Button functions 1 Measure button 2 Add button 3 Area Volume Pythagorean button 4 Measuring reference button 5 Subtract button 6 Historical memory button 7 Unit button 8 ON OFF Clear button...

Страница 3: ...atus 10 Value 1 11 Value 2 Min value 12 Value 3 Max value 13 Summary line latest value calculation result 5 Initial operating and setting Power On Off Long press 8 to switch on off the device The inst...

Страница 4: ...en it s powered on Measurement Unit Long press 7 to change distance unit between m ft in and ft in 6 Operating instructions Single Distance Measurement Press 1 to activate the laser Press 1 again to t...

Страница 5: ...ts of length width perimeter and area are displayed in the screen 1 the first distance 2 the second distance 3 the perimeter 4 the area Volume Measurement Press 3 twice the symbol appears in the funct...

Страница 6: ...symbol appears in the function field on the display Take measurement with the 2 points shown on the figure in numeric sequence the height of the object will be calculated automatically and displayed...

Страница 7: ...summary line Press 8 to delete any measured length and then press 1 to re measure a calculation result Addition Subtraction Addition short press 2 Subtraction long press 5 Take a measurement then pre...

Страница 8: ...ce to operating temperature 255 Received signal too weak or measurement time too long Use target plate or change a good reflective surface 256 Received signal too strong Target too reflective use targ...

Страница 9: ...ed by the version of laser distance meter Exact measuring range is shown on the gift box During daylight or if the target has poor reflection properties please use target plate In favorable conditions...

Страница 10: ...ttery insertion Open the battery compartment then insert batteries according to the direction incon in the compartment For safety please close the compartment with the provided lid after battery inser...

Отзывы: