Histrorical memory
Press
(6) to view histrorical memory, the last 20 measured value will be displayed in reversed order.
Press
(8) to quit historical value viewing.
7. Trouble shooting
All errors or failures will be shown as codes. The following table explains the meaning of codes and
solutions.
Code // Cause // Corrective Measure
204 // Calculation error // Refer to user manual, repeat the procedures.
208 // Excessive current // Please contact your distributer
220 // Battery low // Replace new batteries.
252 // Temperature too high // Let device cool down to operating temperature at 0°C - 40°C.
253 // Temperature too low // Warm up the device to operating temperature.
255 // Received signal too weak or measurement time too long // Use target plate or change a good reflective
surface.
256 // Received signal too strong // Target too reflective, use target plate or do not aim at strong light
objective.
261 // Outside of the range of measurement // Select the measurement distance within the range of mea-
surement.
500 // Hardware error // Switch on/off the device several times. If the symbol still appears, please contact
your dealer for assistance.
8. Specification
Specification // AX-DL100
The maximum measuring range* // 100 m
Measuring accuracy** // ±2 mm
Measuring units // m / ft / in / ft+in
Laser class // Class 2
Laser type // 630-670nm, < 1mW
Single distance measurement //
Min. / max. value //
Area, Volume Measurement //
Indirect Pythagorean theorem //
Continuous measurement //
Addition and subtraction //