![AXIOMATIC AX141100 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/axiomatic/ax141100/ax141100_user-manual_3037095022.webp)
UMAX141100 Version 1.0.6.
Preliminary Documentation – May be subject to change
22 - 36
The default value of the “ECU Address” setpoint is 251 (0xFB), which is the default for an on board
data logger device. The EA will allow the selection of any address between 0 and 253.
It is the
user’s responsibility to select an address that complies with the standard
. The user must also
be aware that since the unit is arbitrary address capable, if another ECU with a higher priority NAME
contends for the selected address, the CAN to Bluetooth device will continue select the next highest
address until it finds one that it can claim. See J1939/81 for more details about address claiming.
Software Identifier
Byte 1 is set to 5, and the identification fields are as follows.
The EA shows all this information in “General ECU Information”, as shown below.
Note: The information provided in the Software ID is available for any J1939 service tool which
supports the PGN -SOFT.
PGN 65242
Software Identification
- SOFT
Transmission Repetition Rate:
On request
Data Length:
Variable
Extended Data Page:
0
Data Page:
0
PDU Format:
254
PDU Specific:
218 PGN Supporting Information:
Default Priority:
6
Parameter Group Number:
65242 (0xFEDA)
Start Position
Length
Parameter Name
SPN
1
1 Byte
Number of software identification fields
965
2-n
Variable
Software identification(s), Delimiter (ASCII “*”)
234