UM AX032200 Version 1.0 28-46
3.4. Miscellaneous Setpoints
The Miscellaneous setpoints are defined in Section 0. Refer to that section for detailed information
on how these setpoints are used. The screen capture below in Figure 8
Error! Reference source
not found.
displays the available setpoints. Table 21 highlights the allowable ranges for each
setpoint.
Figure 8: Screen Capture of Default Miscellaneous Setpoints
Name
Range
Default
Notes
Undervoltage Threshold
6.0…36.0
8.0
Units in [Volts]
Overvoltage Threshold
6.0…36.0
24.0
Units in [Volts]
Current Hysteresis
0…5.0
0.25
Units in [Amps]
Frequency Hysteresis
1
…10000
0.5
Units in [Hz]
RPM Hysteresis
0…2500
10
Units in [RPM]
PWM Hysteresis
5…95
1
Units in [%]
Diagnostic Message Setting Drop List
Diagnostics On
Table 21: Default Miscellaneous Setpoints
3.5. Diagnostic Setpoints
The Diagnostic setpoints are defined in Section 1.6. Refer to that subsection for detailed
information on how these setpoints are used. The screen capture below in Figure 9 displays the
available setpoints for the Power Supply Diagnostic setpoints. Table 22 below highlights the
allowable ranges for each setpoint.